A Study of Abicipar Pegol in Patients With Neovascular Age-related Macular Degeneration

Phase 2
Completed
Conditions
Macular Degeneration
Interventions
Registration Number
NCT02181517
Lead Sponsor
Allergan
Brief Summary

This is a safety and efficacy study of abicipar pegol in patients with neovascular age-related macular degeneration to establish comparability between Japanese and non-Japanese.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
25
Inclusion Criteria
  • Diagnosis of wet age-related macular degeneration in at least 1 eye
  • Best corrected visual acuity of 20/32 to 20/320 in the study eye and 20/200 or better in the fellow eye
Exclusion Criteria
  • Hypersensitivity, allergy, or anaphylactic reaction to iodine
  • Cataract or refractive surgery within the last 3 months
  • History of vitrectomy

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
abicipar pegol 1 mgsham procedureAbicipar pegol 1 mg administered to the study eye by intravitreal injection at day 1, weeks 4 and 8, followed by a sham procedure at weeks 12 and 16.
abicipar pegol 2 mgsham procedureAbicipar pegol 2 mg administered to the study eye by intravitreal injection at day 1, weeks 4 and 8, followed by a sham procedure at weeks 12 and 16.
ranibizumab 0.5 mgranibizumabRanibizumab (Lucentis®) 0.5 mg administered to the study eye by intravitreal injection every 4 weeks from day 1 through week 16.
abicipar pegol 1 mgabicipar pegolAbicipar pegol 1 mg administered to the study eye by intravitreal injection at day 1, weeks 4 and 8, followed by a sham procedure at weeks 12 and 16.
abicipar pegol 2 mgabicipar pegolAbicipar pegol 2 mg administered to the study eye by intravitreal injection at day 1, weeks 4 and 8, followed by a sham procedure at weeks 12 and 16.
Primary Outcome Measures
NameTimeMethod
Change From Baseline in Best Corrected Visual Acuity (BCVA) in the Study Eye at Week 16 Using the Early Treatment Diabetic Retinopathy Study (ETDRS) ScaleBaseline, Week 16

BCVA is measured using an eye chart and is reported as the number of letters read correctly using the ETDRS Scale (ranging from 0 to 100 letters) in the study eye. The lower the number of letters read correctly on the eye chart, the worse the vision (or visual acuity). An increase in the number of letters read correctly means that vision has improved.

Secondary Outcome Measures
NameTimeMethod
Change From Baseline in BCVA in the Study Eye at Week 20 Using the ETDRS ScaleBaseline, Week 20

BCVA is measured using an eye chart and is reported as the number of letters read correctly using the ETDRS Scale (ranging from 0 to 100 letters) in the study eye. The lower the number of letters read correctly on the eye chart, the worse the vision (or visual acuity). An increase in the number of letters read correctly means that vision has improved.

Percentage of Patients With a BCVA Gain of 15 or More Letters in the Study Eye Using the ETDRS ScaleBaseline, Week 20

BCVA is measured using an eye chart and is reported as the number of letters read correctly using the ETDRS Scale (ranging from 0 to 100 letters) in the study eye. The lower the number of letters read correctly on the eye chart, the worse the vision (or visual acuity). An increase in the number of letters read correctly means that vision has improved.

Percentage of Patients With a BCVA Gain of 10 or More Letters in the Study Eye Using the ETDRS ScaleBaseline, Week 20

BCVA is measured using an eye chart and is reported as the number of letters read correctly using the ETDRS Scale (ranging from 0 to 100 letters) in the study eye. The lower the number of letters read correctly on the eye chart, the worse the vision (or visual acuity). An increase in the number of letters read correctly means that vision has improved.

Change From Baseline in Central Retinal Thickness (CRT) in the Study EyeBaseline, Week 16, Week 20

CRT was assessed using spectral domain optical coherence tomography (SD-OCT), a non-invasive diagnostic system providing high-resolution imaging sections of the retina. SD-OCT was performed in the study eye after pupil dilation. A negative change from Baseline indicated improvement.