A Pilot Study to Assess the Effectiveness and Safety of Belotero Balance® Injection for Volume Augmentation of the Infraorbital Hollow
- Conditions
- Correction of Volume Loss in the Infraorbital Hollow Area
- Interventions
- Device: Belotero Balance®
- Registration Number
- NCT03777917
- Lead Sponsor
- Merz North America, Inc.
- Brief Summary
The pilot study aims to define safety, effectiveness, and patient-reported outcomes for Belotero Balance® use in the infraorbital hollows.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 66
- Has right and left infraorbital hollow (IOH) volume deficit with a rating of 2 or 3 (moderate or severe) on the MIHAS.
- Has the same MIHAS score on both IOHs (i.e., IOHs are symmetrical).
- Is at least 22 years of age.
- Ever been treated with fat injections or permanent and/or semi-permanent dermal fillers in the midfacial region.
- Received lower eyelid and/or malar region treatments with any absorbable or temporary fillers such as porcine-based collagen fillers, hyaluronic acid (HA) products, RADIESSE®, poly L-lactic acid (PLLA) or received mesotherapy treatment to the area within the past 24 months or plans to receive such treatments during participation in the study.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description Belotero Balance® Belotero Balance® -
- Primary Outcome Measures
Name Time Method Responder Rate Compared to the Untreated Control Group According to the Merz Infraorbital Hollow Assessment Scale (MIHAS). Baseline up to Month 2 MIHAS was a 5 point scale ranging as: Grade 0 (none to minimal), Grade 1 (mild), Grade 2 (moderate), Grade 3 (severe), Grade 4 (extreme). Responder rate was defined as percentage of participants with treatment response who achieved greater than or equal to (\>=) 1 grade improvement on both IOHs on the MIHAS.
- Secondary Outcome Measures
Name Time Method Change From Baseline in Rasch-Transformed Score for the Face-Q Satisfaction With Eyes Baseline and Month 2 The FACE-Q is a set of standardized patient-reported outcome scales for participants undergoing facial cosmetic procedures. The participants answered 7 questions of the FACE-Q satisfaction with eyes scale using a 4 point scale where: 1 (very dissatisfied), 2 (somewhat dissatisfied), 3 (somewhat satisfied), 4 (very satisfied). The sum scores of the FACE-Q satisfaction with eyes questionnaire and the Rasch-transformed scores ranging from 0 to 100 were summarized by treatment arm. Higher scores reflected a better outcome.
GAIS Scores as Assessed by Participants Baseline up to Month 2 Participants evaluated their IOHs on 7 point rating scale ranging from: +3 (very much improved), +2 (much improved), +1 (improved), 0 (no change), -1 (worse), -2 (much worse), -3 (very much worse).
Number of Participants Reporting One or More Device and/or Injection Related Treatment-emergent Adverse Events (TEAEs) and Device and/or Injection Related Serious TEAEs Treatment Group: Baseline up to Month 13; Untreated Control Group: Baseline up to Month 2 Global Aesthetic Improvement Scale (GAIS) Scores Baseline up to Month 2 7 point rating scale ranging from: +3 (very much improved), +2 (much improved), +1 (improved), 0 (no change), -1 (worse), -2 (much worse), -3 (very much worse).
Responder Rate in the Treatment Group and the Untreated Control Group According to MIHAS as Assessed by Independent Panel Reviewers Baseline up to Month 2 MIHAS was a 5 point scale ranging as: 0 (none to minimal), 1 (mild), 2 (moderate), 3 (severe), 4 (extreme). Responder rate was defined as percentage of participants with treatment response who achieved \>=1 improvement on both IOHs compared to baseline. A participant was considered a responder if a treatment response of at least a 1-point change on both IOHs was determined by independent panel reviewers.
Trial Locations
- Locations (3)
Private Practice, Merz Investigational Site #0010413
🇺🇸New York, New York, United States
Center for Sight, Merz Investigational Site #0010414
🇺🇸Sarasota, Florida, United States
Center for Laser and Facial Surgery, Merz Investigational Site #0010353
🇺🇸Nashville, Tennessee, United States