Skip to main content
Clinical Trials/NCT04618419
NCT04618419CompletedNot Applicable

Internal Jugular Vein Sonogram Versus Electrical Cardiometry For Assessment Of Fluid Responsiveness In Adult Undergoing Coronary Artery Bypass Graft Surgery

Ahmed Abd El-Rahim Abd El-Hamid Hammad1 site in 1 country40 target enrollmentStarted: May 10, 2019Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Sponsor
Enrollment
40
Locations
1
Primary Endpoint
fluid responsiveness after fluid challenge

Study Overview

Brief Summary

The primary aim of the study is to assess the reliability of predicting fluid responsiveness in adults undergoing coronary artery bypass graft surgery using sonogram of the internal jugular vein for assessment of vessel distensibility in relation to stroke volume variation (SVV) measaured by electrical cardiometry.

The secondary aim is to evaluate the ability of thoracic fluid content (TFC) measured by electrical cardiometry to be an additive value for the assessment of fluid responsiveness.

Detailed Description

Fluid management is one of the most important treatments for stabilizing hemodynamics in patients after cardiac surgery.Electrical Cardiometry is a method for the non-invasive determination of stroke volume (SV), cardiac output (CO), stroke volume variation (SVV) and other hemodynamic parameters in adults, children, and neonates based on measurement of thoracic electrical bioimpedance and has been validated against "gold standard" methods such as thermodilution method of deriving CO using a pulmonary artery catheter (PAC).

The IJV is, technically, much more easily accessible for sonographic visualization than the IVC, and measurement of the IJV does not require transesophageal echocardiography (TEE). Internal jugular vein distensibility index (IJVDI) has been studied in several studies but its reliability has not been well confirmed in patients during cardiac surgery.

This is a prospective observational study of adults undergoing coronary artery bypass graft surgery . The primary aim of the study is to assess the reliability of predicting fluid responsiveness in adults undergoing coronary artery bypass graft surgery using sonogram of the internal jugular vein for assessment of vessel distensibility in relation to stroke volume variation (SVV) measaured by electrical cardiometry.The secondary aim is to evaluate the ability of thoracic fluid content (TFC) measured by electrical cardiometry to be an additive value for the assessment of fluid responsiveness.

Volume responsiveness will be independently assessed by IJV sonogram and electrical cardiometry in following times

  1. After induction of anesthesia.
  2. After transfusing 6 ml / kg of hydroxyethyl starch (HES) 6% before sternotomy.
  3. After closure of the sternum and transfusion of patient's blood.
  4. Immediately before transferring the patient to ICU and stabilization of hemodynamic parameters by giving fluids needed to patient.
  5. Immediately after transferring the patient to ICU and stabilization of hemodynamic parameters by giving fluids needed to patient.
  6. After 2 hour of ICU admission.
  7. Before weaning from mechanical ventilation Fluid responsiveness will be assessed by examining SVV with a threshold of the SVV = 12% allow discrimination between Responders and Non-responders

Study Design

Study Type
Observational
Observational Model
Case Control
Time Perspective
Prospective

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Adults (>18 years old) Able to provide advanced informed consent Planned for elective CABG surgery

Exclusion Criteria

  • Age < 18 years
  • Severely reduced preoperative left ventricular ejection fraction < 40 %
  • Significant cardiac arrhythmia.
  • Significant valvular heart disease.
  • Clinically evident pulmonary disease.
  • Bilaterally inserted venous catheters (jugular or subclavian vein)
  • History of radiotherapy or surgery of the neck region.
  • Inability to obtain interpretable ultrasound images due to a difficult acoustic window.

Outcomes

Primary Outcomes

fluid responsiveness after fluid challenge

Time Frame: 24 hours from the start of surgery

Correlation between SVV and IJVDI

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor
Ahmed Abd El-Rahim Abd El-Hamid Hammad
Sponsor Class
Other
Responsible Party
Sponsor Investigator
Principal Investigator

Ahmed Abd El-Rahim Abd El-Hamid Hammad

Residentat department of anaesthesia and surgical intensive Care

Alexandria University

Study Sites (1)

Loading locations...

Similar Trials