Comprehensive and Comparative Analysis of Venous Oxygen Saturation During ECMO Support: a Pilot Study

University Hospital, Lille2 个研究点 分布在 1 个国家目标入组 48 人2021年8月5日
干预措施ECMO flow

概览

阶段
不适用
干预措施
ECMO flow
疾病 / 适应症
Cardiogenic Shock
发起方
University Hospital, Lille
入组人数
48
试验地点
2
主要终点
the intraclass correlation coefficient (ICC) between SECMOO2, and ScVO2 in the initial assist condition of 2-3 L/min (after 30 minutes of stability)
状态
已完成
最后更新
10天前

概览

简要总结

Extracorporeal veno-arterial membrane oxygenation" (ECMO-VA), are used to manage refractory cardiogenic shocks by replacing the failed "heart-lung" block. The Extracorporeal Life Support Organisation guidelines considers that the effectiveness of these techniques must be evaluated on the adequacy of tissue perfusion biomarker, of which is O2 saturation of venous blood found in the pulmonary artery using a Swan-Ganz catheter (SVO2) or in the superior vena cava/right atrium using a central venous catheter (ScVO2). During ECMO support, it can be also measured directly in the venous ECMO cannula (SmVO2).

However, due to the difference in tips locations of the venous cannula of ECMO-VA, the central venous catheter and the Swan-Ganz catheter, and rheological issues, the SmVO2, SVO2 and ScVO2 values obtained may be different.

Further we hypothesised that the level of admission flow may also affect the correlation between these different variables.

The aim of this experimental study is to investigate the concordance of the saturation of venous blood collected from these 3 measurement sites.

The primary objectives is to compare the concordance of ScVO2 and the SmVO2, the two more easily and systematically available variables

The secondary objectives were :

  1. to evaluate the concordance of the 3 variables describing oxygen saturation
  2. to analyse the primary objectives during prespecified and calibrated flow changes
  3. analyse the association between these 3 variables with prognosis variables (Perfusion index, lactatemia, CO2 veno-arterial differences, SOFA score, SAPS II, successful weaning from the ECMO)
  4. analyse in an ancilary study the concordance between SmVO2 measured using blood sample and the value obtained using a continuous monitoring of SVO2 through the circuit.

详细描述

Extracorporeal veno-arterial membrane oxygenation" (ECMO-VA), are used to manage refractory cardiogenic shocks by replacing the failed "heart-lung" block. The Extracorporeal Life Support Organisation guidelines considers that the effectiveness of these techniques must be evaluated on the adequacy of tissue perfusion biomarker, of which is O2 saturation of venous blood found in the pulmonary artery using a Swan-Ganz catheter (SVO2) or in the superior vena cava/right atrium using a central venous catheter (ScVO2). During ECMO support, it can be also measured directly in the venous ECMO cannula (SmVO2). However, due to the difference in tips locations of the venous cannula of ECMO-VA, the central venous catheter and the Swan-Ganz catheter, and rheological issues, the SmVO2, SVO2 and ScVO2 values obtained may be different. Further we hypothesised that the level of admission flow may also affect the correlation between these different variables. The aim of this experimental study is to investigate the concordance of the saturation of venous blood collected from these 3 measurement sites. The primary objectives is to compare the concordance of ScVO2 and the SmVO2, the two more easily and systematically available variables The secondary objectives were : 1. to evaluate the concordance of the 3 variables describing oxygen saturation 2. to analyse the primary objectives during prespecified and calibrated flow changes 3. analyse the association between these 3 variables with prognosis variables (Perfusion index, lactatemia, CO2 veno-arterial differences, SOFA score, SAPS II, successful weaning from the ECMO) 4. analyse in an ancilary study the concordance between SmVO2 measured using blood sample and the value obtained using a continuous monitoring of SVO2 through the circuit.

注册库
clinicaltrials.gov
开始日期
2021年8月5日
结束日期
2025年3月6日
最后更新
10天前
研究类型
Interventional
研究设计
Single Group
性别
All

研究者

发起方
University Hospital, Lille
责任方
Sponsor

入排标准

入选标准

  • Weight \>50 kg
  • Veno-arterial ECMO with impending removal (for recovery, heart transplantation or LVAD/BIVAD implantation or support futility)
  • Venous catheter tip positioned in the superior vena cava or right heart
  • Arterial line for blood pressure monitoring
  • Given informed consent

排除标准

  • Pregnancy
  • Absence of arterial line or central venous catheter
  • Hemodynamic instability under ECMO support
  • Malposition of ECMO venous canula

研究组 & 干预措施

patients

patients receiving temporary veno-arterial assistance whose weaning, or transfer to a heart transplant, or to long-term assistance or discontinuation is envisaged.

干预措施: ECMO flow

结局指标

主要结局

the intraclass correlation coefficient (ICC) between SECMOO2, and ScVO2 in the initial assist condition of 2-3 L/min (after 30 minutes of stability)

时间窗: after 30 minutes of stability in the initial assistance condition (condition 1)

the intraclass correlation coefficient (ICC) between SECMOO2, and ScVO2 in the initial assist condition of 2-3 L/min (after 30 minutes of stability). Due to the importance of patient position, measurements will be standardized in supine position or with head of bed inclination less than 30% SVO2 measured on ECMO circuit and in patient's superior vena cava.

次要结局

  • ICC between SVO2 and SECMOO2 measured after 30 minutes of stability in the initial assist condition (2-3 L/min), in patients with a Swan-Ganz catheter(after 30 minutes of stability in the initial assistance condition (condition 1))
  • ICC between ScVO2 and SVO2 measured after 30 minutes of stability(after 30 minutes of stability in the initial assistance condition (condition 1))
  • Association between changes in SCVO2 and SECMOO2 measured at differents flow levels(More than 30 minutes of stability between each condition)
  • Association between changes in SVO2 and SECMOO2 measured at differents flow levels(More than 30 minutes of stability between each condition)
  • Association between each SVO2 derived variable with macrocirculatory, microcirculatory variables(More than 30 minutes of stability between each condition)