跳至主要内容
临床试验/NCT03637088
NCT03637088已完成不适用

Acute Exposure to Hypoxia in Precapillary Pulmonary Hypertension: Physiological and Clinical Effects at Rest and During Exercise

University of Zurich2 个研究点 分布在 1 个国家目标入组 28 人开始时间: 2018年8月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
28
试验地点
2
主要终点
Echocardiographic assessment under hypoxia (FiO2: 15.1)

研究概览

简要总结

Randomized crossover trial in patients with Pulmonary Hypertension (PAH, CTEPH) to assess the acute response to simulated altitude (FiO2:15.1, equivalent to 2500m above sea level) on pulmonary artery pressure and right heart function (Echo).

详细描述

Low altitude baseline measurements will be performed in Zurich (460m asl) including Echocardiography, Right heart catheterization, (six-minute walk test) 6MWT, pulmonary function test, clinical assessment and blood gas Analysis.

Randomly assigned to the order of testing, the participants will be tested under simulated altitude (FiO2: 15.1% with the "AMC Altitrainer") and shamed altitude with the same device.

Several times within the exposure, the pulmonary artery pressure and the right heart function will be assessed by echo.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Prevention
盲法
Single (Participant)

盲法说明

The allocated gas mixture will not be disclosed to the patient since he will breath through a facemask during both interventions.

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Informed consent
  • PH diagnosed according to internation Guidelines: mean pulmonary artery pressure (mPAP) ≥ 25 mmHg along with a (pulmonary artery wedge pressure) PAWP ≤15 mmHg during right heart catheterization at the time of initial diagnosis
  • PH class 1 (PAH) or 4 (CTEPH)
  • Stable condition, on the same medication for > 4 weeks
  • Patient live permanently at an altitude < 1000m asl.

排除标准

  • Resting partial Oxygen pressure (PaO2) ≤7.3 kilopascal (kPA) corresponding to the requirement of long-term oxygen therapy > 16hour daily (nocturnal oxygen therapy alone is allowed)
  • Severe daytime hypercapnia (pCO2 > 6.5 kPa)
  • Susceptibility to high altitude related diseases (AMS, high-altitude pulmonary edema (HAPE), etc.) based on previous experienced discomfort at altitudes.
  • Exposure to an altitude >1500m for ≥3 nights during the last 4 weeks before the study participation
  • Residence > 1000m above sea level
  • Inability to follow the procedures of the study, e.g. due to language problems, psychological disorders, neurological or orthopedic problems with walking disability
  • Women who are pregnant or breast feeding

研究组 & 干预措施

Order air-hypoxia

Experimental

The participants will be exposed to shamed hypoxia (FiO2: 20.9% equivalent to sea level and consecutively to simulated altitude (FiO2: 15.1% equivalent to 2500m above sea level) administered by an altitude Simulator ("Altitrainer, SMTEC"), simulated altitude (FiO2: 15.1%), with a facemask.

干预措施: Simulated Altitude (FiO2: 15.1%) (Device)

Order air-hypoxia

Experimental

The participants will be exposed to shamed hypoxia (FiO2: 20.9% equivalent to sea level and consecutively to simulated altitude (FiO2: 15.1% equivalent to 2500m above sea level) administered by an altitude Simulator ("Altitrainer, SMTEC"), simulated altitude (FiO2: 15.1%), with a facemask.

干预措施: Shamed Hypoxia (FiO2: 20.9) (Device)

Order hypoxia-air

Experimental

The participant will be exposed to hypoxia (FiO2, 15.1% equivalent to 2500m above sea level), simulated altitude (FiO2: 15.1%), and consecutively to shamed hypoxia (FiO2, 20.9%) administered by an altitude simulator ("Altitrainer, SMTEC") with a facemask.

干预措施: Simulated Altitude (FiO2: 15.1%) (Device)

Order hypoxia-air

Experimental

The participant will be exposed to hypoxia (FiO2, 15.1% equivalent to 2500m above sea level), simulated altitude (FiO2: 15.1%), and consecutively to shamed hypoxia (FiO2, 20.9%) administered by an altitude simulator ("Altitrainer, SMTEC") with a facemask.

干预措施: Shamed Hypoxia (FiO2: 20.9) (Device)

结局指标

主要结局

Echocardiographic assessment under hypoxia (FiO2: 15.1)

时间窗: 2 hours

Pulmonary artery pressure measured by echo (TTE)

次要结局

  • Echocardiographic assessment of the right heart under hypoxia (FiO2: 15.1)(2 hours)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验