Novel Cardiac Signal Processing System for Electrophysiology Procedures

BioSig Technologies, Inc.3 个研究点 分布在 1 个国家目标入组 104 人开始时间: 2019年11月12日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
104
试验地点
3
主要终点
Safe and effective use of the PURE EP 2 system based on system specifications and recorded within the Case Report Form (CRF).

研究概览

简要总结

This study is designed to collect parallel intracardiac signal data during pre-defined periods of clinical interest from the PURE EP system and the existing signal recording and mapping systems.

The collected signals will then undergo BLINDED, CONTROLLED evaluation by unbiased electrophysiologist reviewer(s) to determine whether the PURE EP signals provides additional or clearer diagnostic information.

详细描述

Cardiac electrophysiologists rely on the display of electrograms when performing electrophysiology (EP) studies and catheter ablations in patients with arrhythmias. To achieve effective outcomes without complications, it is vital that the recording system enables the recognition of clearly abnormal (scared myocardium) and normal electrical signals.

Current recording systems have limitations in that it can be difficult to clearly distinguish a true cardiac signal from noise or artifact. This is particularly true when pacing the heart and when ablating abnormal myocardial tissue, components of the conduction system or epicardial structures. Therefore, improvement of the fidelity of signals obtained from EP recording systems is needed to enhance identification of the most effective targets for ablation.

There are several standard electrophysiology recording systems in use today, such as the commonly used GE/Prucka CardioLab recording system ("Prucka") which would benefit from additional features in order to improve the ability to record, discriminate and analyze signals from the heart. BioSig Technologies, Inc. ("BioSig") has developed an electrophysiology signal processing system, the PURE EP™ System, which may allow electrophysiologists to better characterize arrhythmogenic tissue during ablation procedures. Specifically, the PURE EP™ System's higher sampling rate and higher dynamic range allow improved visualization of low amplitude signals, especially those temporally situated near low frequency, high amplitude signals or large high-frequency signals.

This multi-center, prospective, non-randomized, observational study will involve at least five patients undergoing elective cardiac ablation procedure for tachycardias such as atrial fibrillation, atypical atrial flutter, ischemic ventricular tachycardia, or symptomatic premature ventricular contractions (PVCs). The existing recording/mapping system clocks will be synchronized to the PURE EP clock prior to each procedure. At the beginning of the procedures, all systems will be optimized for best signal display based on the physician preference. During the ablation procedures, annotations will be captured on the PURE EP system based on pre-determined clinically relevant events defined in this protocol (example - before and after successful ablation therapy).

After the procedures, parallel signal data samples will be harvested from all the systems using the procedure annotations and the time stamps as a guide. Once the signal data is harvested, cleaned, and organized, the individual signal samples will be reviewed in a blinded, controlled fashion by a group of independent, unbiased electrophysiologist(s).

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Indication for cardiac ablation treatment
  • Signed informed consent

排除标准

  • contraindication to electrophysiology study or ablation
  • Enrollment in any other ongoing arrhythmia study protocol
  • Active Infection or sepsis
  • Pregnancy or lactation
  • < 18 years of age

结局指标

主要结局

Safe and effective use of the PURE EP 2 system based on system specifications and recorded within the Case Report Form (CRF).

时间窗: Throughout the cardiac ablation procedure

The primary aim of this study is to further establish the safe and effective use of the PURE EP System during cardiac ablation in the EP Laboratory in a post-market environment. The PURE EP System will be installed to run in parallel to existing mapping and recording systems already in use in the EP lab. Each system will be optimized for viewing intracardiac signals based on the physician preference. The existing systems will serve as the primary method of viewing intracardiac signals and the PURE EP system will be redundant. The intracardiac signals from the PURE EP system will be compared to existing recording and mapping system signals generated in real-time during each ablation procedure. The PURE EP system signals will be monitored by the physician investigator and a company clinical representative to validate the PURE EP 2 system runs as intended based on the system manual and meets expected standards for displaying signals.

次要结局

  • Assess the quality of the PURE EP 2 intracardiac signals when compared to existing recording and mapping systems as determined by controlled survey of blinded, independent expert electrophysiology reviewers.(After the collection of signal samples from at least (5) subjects and until study completion)