跳至主要内容
临床试验/NCT03034798
NCT03034798已完成不适用

The Effects of Basal Insulin Suspension at the Start of Exercise on Blood Glucose Levels During Continuous vs. Circuit-based Exercise in Individuals With Type 1 Diabetes on CSII

York University0 个研究点目标入组 12 人开始时间: 2015年1月14日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
12
主要终点
Blood glucose concentrations

研究概览

简要总结

The purpose of the study is to determine the effects of insulin suspension at start of exercise in individuals with type 1 diabetes. A total of 3 sessions will be required for this project. The first will be a familiarization session that requires completed informed consent, anthropometric measurements (height, weight, body fat percentage), questionnaires, and a test of maximal aerobic fitness. The remaining 2 sessions will be steady-state aerobic exercise as well as circuit exercise.

详细描述

Written informed consent will be collected on the first day during the familiarization session from all individuals that wish to participate. A researcher will provide a brief explanation on how the continuous glucose monitor (CGM) works (Medtronic Inc., Canada) during the first visit to the laboratory. They will also describe how the CGM sensor insertion process will occur for those participants who have not worn one in the past. The participant will clean and sanitize the area and insert the CGM superficially in the skin themselves and connect the transmitter device to the sensor. The CGM will be worn for a total of 7 days and then removed by the participant and returned to the researcher to be downloaded. The sports armband will also be placed on the left upper arm and be worn continuously for 7 days. The principal student investigator (PSI) or principal investigator (PI) will provide all participants with information about the sports armband and place it on the skin immediately following. This device simply sits on the surface of the skin, but has a specific placement and activation and must be applied by the PSI or PI. Finally, during exercise visits, the Zephyr bioharness will be connected just below chest level and around the rib cage. This device is sits on top of the skin simply like an elastic band around the rib cage. The bioharness will only be worn during exercise visits and disconnected at the end of each activity.

Blood glucose levels will be monitored frequently during exercise using a Contour Link glucometer (Bayer, Canada). Participants will use personal lancing device for finger pokes, but the investigators will provide the glucometer and test strips. Each blood sugar check will be recorded in the data binder along with carbohydrate intake, any changes in basal rate or pump settings, and food intake. If blood glucose levels reach 3.9 mmol/L or less, participants will be asked to stop activity immediately and consume fast-acting carbohydrates (i.e. Dextrose tablets (Dex4, USA)). 15-minutes after ingestion of carbohydrates, blood glucose will be tested again before allowing the individual to return to activity safely. On the last day of testing, participants will be asked to return the CGM, sports armband, and bioharness to the research team. The data will later be uploaded and analyzed.

Patients will undergo a fitness assessment (maximal aerobic capacity) during visit 1 and perform 40-minutes of continuous (treadmill jogging) and 40-minutes of intermittent (calisthenics) high-intensity type exercises (visit 2 and 3). Upon entry to the laboratory, participants will be asked to check blood glucose levels using the glucometer provided. The first exercise session will consist of a 40-minute treadmill walk/jog at ~40-50% of VO2max. The second exercise session will include various aerobic and anaerobic activities including push-ups, plank, jumping jacks, high knees, etc. Regular finger capillary blood samples will be collected every 10-minutes during exercise. Once the exercise session is complete, participants will be asked to remain in the laboratory for 30-minutes for additional blood glucose measurements and to ensure hypoglycemic episodes do not occur post-exercise. Participants will be given the contour link glucometer to monitor glucose levels throughout the evening and night.

研究设计

研究类型
Observational
观察模型
Case Crossover
时间视角
Prospective

入排标准

年龄范围
18 Years 至 55 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Have had diabetes for > 1 year
  • Currently treated with continuous subcutaneous insulin infusion (CSII)/insulin pump therapy for at least 6 months
  • Fair-to-good glycemic control (last HbA1c ≤ 9.0%)

排除标准

  • Frequent and unpredictable hypoglycemia
  • Unable to exercise on a regular basis due to an injury or other restriction
  • Using an insulin pump and switch to injections (or vice versa) in the last two months
  • Have conditions that would make exercise unsafe (e.g. high blood pressure)
  • Take medications in the class of drugs called 'beta-blockers'
  • A woman who is pregnant, planning pregnancy, or breastfeeding

结局指标

主要结局

Blood glucose concentrations

时间窗: Approximately 2 hours

Whole blood glucose concentrations were measured using a handheld glucometer every 10-minutes before, during, and after both exercise conditions.

次要结局

  • Participants estimated blood glucose concentration(40-minutes during exercise and 10-minutes post-exercise)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Michael Riddell

Professor

York University