Clinical Evaluation of a Laser Heated, Fiberoptic-Coupled Radiation Dose Verification System
- Conditions
- Neoplasm
- Registration Number
- NCT00026871
- Lead Sponsor
- National Cancer Institute (NCI)
- Brief Summary
We propose to determine the response of a newly developed laser heated, vycor glass fiberoptic radiation dosimetry system to ionizing radiation in a clinical radiotherapy environment. Present systems measure only total dose or have limitations, such as instability, non-linearity, excessive size or a decoupled measurement system, making them unsuitable in a variety of clinical applications. This fiberoptic coupled dosimetry system is a new and innovative technology application which allows on-line measurement of instantaneous dose rate and total dose never before achievable. It offers a clear advantage in patient treatment delivery, allowing on-line corrections essential to a new generation of radiotherapy treatment machines with development of beam intensity modulation as an adjunct to 3D conformal therapy. It also has the advantage of submillimeter size and is minimally invasive, making it ideal for brachytherapy.
This system has the potential for stable, accurate, reproducible, clinically feasible measurements of total dose and dose rate. The output of this system will be measured under various clinical conditions encountered in a clinical setting and compared against existing thermolumeniscent and diode dosimetry standards. Initial measurements will use a tissue equivalent phantom for depth dose and accuracy measurements. Additional studies will include dosimetric measurements of routine clinical treatment setups on patients receiving therapeutic irradiation.
- Detailed Description
We propose to determine the response of a newly developed laser heated, vycor glass fiberoptic radiation dosimetry system to ionizing radiation in a clinical radiotherapy environment. Present systems measure only total dose or have limitations, such as instability, non-linearity, excessive size or a decoupled measurement system, making them unsuitable in a variety of clinical applications. This fiberoptic coupled dosimetry system is a new and innovative technology application which allows on-line measurement of instantaneous dose rate and total dose never before achievable. It offers a clear advantage in patient treatment delivery, allowing on-line corrections essential to a new generation of radiotherapy treatment machines with development of beam intensity modulation as an adjunct to 3D conformal therapy. It also has the advantage of submillimeter size and is minimally invasive, making it ideal for brachytherapy.
This system has the potential for stable, accurate, reproducible, clinically feasible measurements of total dose and dose rate. The output of this system will be measured under various clinical conditions encountered in a clinical setting and compared against existing thermolumeniscent and diode dosimetry standards. Initial measurements will use a tissue equivalent phantom for depth dose and accuracy measurements. Additional studies will include dosimetric measurements of routine clinical treatment setups on patients receiving therapeutic irradiation.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 20
Not provided
Not provided
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
National Cancer Institute (NCI)
🇺🇸Bethesda, Maryland, United States