MedPath

Acetabular Fracture Reduction Assessment

Not yet recruiting
Conditions
Acetabular Fracture
Interventions
Other: post operative measure of reduction
Registration Number
NCT04073329
Lead Sponsor
Assiut University
Brief Summary

It is widely accepted in the literature that quality of acetabular fracture reduction is one of the most important factor for the outcome. To obtain best results, anatomical reduction has to be obtained. Intra-operative radiographic assessment depends mainly on plain x-ray. Plain x-ray alone is not enough for post-operative assessment as it depends mainly on reduction of the dome with concentricity of the hip.

Detailed Description

It is widely accepted in the literature that quality of acetabular fracture reduction is one of the most important factor for the outcome. To obtain best results, anatomical reduction has to be obtained. Intra-operative radiographic assessment depends mainly on plain x-ray. Plain x-ray alone is not enough for post-operative assessment as it depends mainly on reduction of the dome with concentricity of the hip. Complex fractures with multi-fragmentary fracture pattern, impacted fragments (marginal or roof), fractures with osteo-chondral loss and associated head of femur injuries, pose problems with reduction assessment using both Plain x-ray and CT due to lack of clear standardized way of assessment. Matta criteria has been used widely in the literature for assessment, however it lacks some important criteria which directly related to the functional outcome. Few papers in the literature address this problem and reporting some ways for assessment but with lack of testing and reproducibility.

Since there is in our level 1 trauma center a lot of cases of acetabular fractures that is admitted yearly to our center Purpose of our study is to use those methods for our cases in order to test their validity and reproducibility

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
300
Inclusion Criteria
  • Isolated displaced acetabular fractures
  • Skeletally mature patients
Exclusion Criteria
  • Skeletally Immature

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
CTpost operative measure of reductionmeasure the accuracy of reduction by Verbeek method
Plain x raypost operative measure of reductionmeasurement the accuracy of post operative reduction by Matta method
Primary Outcome Measures
NameTimeMethod
Ability of CT scans and plain radiographs to detect residual articular steps and gaps after healing of acetabular fractures managed by open reduction and internal fixation.1 year

measurement was used to grade quality of reduction according to Matta's system . In accordance with prior studies, adequate (or anatomic) reductions with 0-1 mm of displacement were compared to inadequate (imperfect or poor) reductions with \> 1 mm displacement . For the CT-based method, postoperative pre-digital (prior to 2000) and digital CT images were independently assessed in the axial, sagittal, and coronal planes, and residual gap and step displacement were measured along the articular surface at the level of the weight-bearing dome. Adequate reductions on postoperative CT were defined as \< 1 mm step and \< 5 mm gap displacement and inadequate reductions as ≥ 1 mm step and/or ≥ 5 mm gap displacement.

Secondary Outcome Measures
NameTimeMethod
© Copyright 2025. All Rights Reserved by MedPath