Skip to main content
Clinical Trials/NCT05776030
NCT05776030
Recruiting
Not Applicable

Multi-speed Ergonomic Wheelchair

VA Office of Research and Development2 sites in 1 country30 target enrollmentJuly 18, 2024

Overview

Phase
Not Applicable
Intervention
Single Speed Ergonomic Wheelchair
Conditions
Spinal Cord Diseases
Sponsor
VA Office of Research and Development
Enrollment
30
Locations
2
Primary Endpoint
20 Meter Push Test - Carpet, Gear Ratio 1:1
Status
Recruiting
Last Updated
12 days ago

Overview

Brief Summary

Over one million Americans rely on their upper extremities for manual wheelchair propulsion. Shoulder overuse injuries are prevalent among manual wheelchair users and these injuries often result in shoulder pain. Severe shoulder pain can lead some wheelchair users to transition from manual to powered mobility, complicating transportation, and reducing independence in activities of daily living. This project will expand the understanding of a new wheelchair design that allows better positioning of the hand rims and allows for different gearing. The investigators will study steady-state propulsion efficiency with different gear ratios and develop a new system with multiple gear ratios. The advanced gearing will allow for a low gear when initiating movement, going uphill, or when moving over carpet, and then a higher gear option for movements on hard flat level terrain. This system has the potential to dramatically improve shoulder ergonomics and reduce pain in many future manual wheelchair users.

Detailed Description

The Minneapolis Adaptive Design \& Engineering (MADE) Program has recently developed ergonomic wheelchairs that use a chain drive system to place the hand rims in an ergonomic position while keeping the rear drive wheels posterior for a stable base of support. The investigators' ergonomic wheelchair's forward hand rim positioning allows for a more efficient push along a longer arc length of the hand rims, without sacrificing wheelchair stability or shoulder ergonomics. The ergonomic wheelchair's chain drive allows for individualized gear ratios to suit each wheelchair user's needs; however, the investigators have not yet studied this feature. Thus, the objectives of this proposed work are to (1) explore the effect of different gearing options on Veteran wheelchair user steady-state propulsion efficiency, and (2) develop a multi-speed ergonomic wheelchair allowing for lower gears during difficult situations (initiating movements, moving over carpeting) and higher gears for steady-state movements on flat surfaces. The investigators will recruit 18 Veterans with SCI/D to participate in a cross-over study of the ergonomic wheelchair with three gear ratios (3:2 (low), 1:1 (normal), and 2:3 (high)). The investigators will use two measurement approaches to assess efficiency: (1) work done at the pushrim hubs to move the wheelchair in Joules (J), and (2) the measurement of energy (kCal: kilocalories) expended by the Veteran to move the wheelchair. Similar to miles per gallon in a car, the investigators will calculate distances traveled in meters (m) per energy units (m/J and m/kCal) as the measures of efficiency. The investigators hypothesize that (H1) Higher gear ratios will be more efficient (higher m/J) on hard level terrain than lower gear ratios, (H2) Lower gear ratios will be more efficient (higher m/J) for inclined terrain than higher gear ratios, (H3) Lower gear ratios will be more efficient (higher m/J) for carpeted terrain than higher gear ratios, and (H4) Veterans will be more efficient (higher m/kCal) in moving the wheelchair during the 6MPT on hard level terrain when using higher gear ratios compared with lower gear ratios. In addition to steady-state measures, the investigators will also explore the effects of gearing on propulsion initiation and expect lower gear ratios will be beneficial for initiation on all terrains. The investigators will then recruit 12 Veterans to try a new multi-speed ergonomic wheelchair that has two hand rims per side - one in a lower gear and the other in a higher gear. The proposed system does not require manual or electric shifting between gears. Instead, the Veteran can use the lower gear to initiate movements and then "shift on the fly" by simply pushing on the other hand rim. Veterans will return to the laboratory and provide feedback as the design is iteratively improved. Quantitative and qualitative data will be captured to determine feasibility of this approach and to promote commercialization of the multi-speed ergonomic wheelchair. Throughout the project, the team will work closely with VA's Technology Transfer Program and the TechLink Center to find an industry partner for this work. The investigators' team has demonstrated the ability to develop rehabilitation products into commercially licensed products. The investigators will follow a similar stage-gate process in this development project to maximize the chances for successful commercialization of the modular multi-speed ergonomic wheelchair.

Registry
clinicaltrials.gov
Start Date
July 18, 2024
End Date
March 31, 2027
Last Updated
12 days ago
Study Type
Interventional
Study Design
Crossover
Sex
All

Investigators

Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • Inclusion criteria:
  • Uses manual wheelchair daily
  • Mass less than 125 kg
  • Age 18 or older
  • Decisional competency to provide consent and cognitive ability to participate fully in study procedures
  • Body size appropriate to fit the wheelchairs (16" and 18" seat widths)

Exclusion Criteria

  • Exclusion criteria:
  • Sitting surface pressure injuries
  • Flap procedure to address pressure injury less than one year earlier
  • Unable to obtain clinically acceptable seating system for study wheelchairs
  • Not able to propel a manual wheelchair
  • Upper extremity or spine issues which would make this study unsafe, such as recent surgeries, fractures, tendon tears or nerve impingement (will be assessed by SCI physician - Dr. Byron Eddy)
  • Medical conditions such as cardiovascular disease, pulmonary disease, or other conditions that would make the study procedures unsafe (will be assessed by SCI physician - Dr. Byron Eddy)

Arms & Interventions

Ergonomic Wheelchair Gear Testing

This study has two aims. The first aim will have participants use a single speed ergonomic wheelchair to test three different gear ratio set ups (3:2, 1:1, 2:3).

Intervention: Single Speed Ergonomic Wheelchair

Multispeed Testing - Ergonomic Wheelchair

The second aim will have participants compared to the participant's standard wheelchair to a multi-speed (2 gear ratios) ergonomic wheelchair.

Intervention: Multi-Speed Ergonomic Wheelchair

Multispeed Testing - Standard Wheelchair

The second aim will have participants compared to the participant's standard wheelchair to a multi-speed (2 gear ratios) ergonomic wheelchair.

Intervention: Multi-Speed Ergonomic Wheelchair

Outcomes

Primary Outcomes

20 Meter Push Test - Carpet, Gear Ratio 1:1

Time Frame: up to 4 weeks after enrollment

Individuals self-propel a wheelchair 20 meters at their chosen pace

20 Meter Push Test - uphill, Gear Ratio 3:2

Time Frame: up to 4 weeks after enrollment

Individuals self-propel a wheelchair 20 meters at their chosen pace

20 Meter Push Test - level surface, Gear Ratio 2:3

Time Frame: up to 4 weeks after enrollment

Individuals self-propel a wheelchair 20 meters at their chosen pace

20 Meter Push Test - level surface, Gear Ratio 1:1

Time Frame: up to 4 weeks after enrollment

Individuals self-propel a wheelchair 20 meters at their chosen pace

6 Minute Push Test - Gear Ratio 1:1, Temporal/Spatial

Time Frame: up to 4 weeks after enrollment

Distance (m) and number of pushes will be collected during this test.

6 Minute Push Test - Gear Ratio 3:2, Temporal/Spatial

Time Frame: up to 4 weeks after enrollment

Distance (m) and number of pushes will be collected during this test.

600 Meter Course - Usual Wheelchair, Rating of Perceived Exertion (RPE)

Time Frame: up to 4 weeks after enrollment

The distance of 600 meters is used clinically to assess community ambulation ability and can be used to determine if a power wheelchair is needed. The 600 meter course will include several turns, carpeting, and starting/stopping the wheelchair. Participants will be instructed to complete the course at a comfortable pace and RPE will be asked at the end of the course.

600 Meter Course - Multispeed Wheelchair, Rating of Perceived Exertion (RPE)

Time Frame: up to 4 weeks after enrollment

The distance of 600 meters is used clinically to assess community ambulation ability and can be used to determine if a power wheelchair is needed. The 600 meter course will include several turns, carpeting, and starting/stopping the wheelchair. Participants will be instructed to complete the course at a comfortable pace and RPE will be asked at the end of the course.

Mobility-Related ADL - Usual Wheelchair, Timed (seconds)

Time Frame: up to 4 weeks after enrollment

This is a standardized, timed circuit of simulated mobility-related ADL tasks to simulate a morning ADL routine.

20 Meter Push Test - uphill, Gear Ratio 1:1

Time Frame: up to 4 weeks after enrollment

Individuals self-propel a wheelchair 20 meters at their chosen pace

20 Meter Push Test - Carpet, Gear Ratio 3:2

Time Frame: up to 4 weeks after enrollment

Individuals self-propel a wheelchair 20 meters at their chosen pace

6 Minute Push Test - Gear Ratio 1:1, Metabolic (kCal/min)

Time Frame: up to 4 weeks after enrollment

Oxygen Uptake (VO2: L/min), Carbon dioxide production (VCO2: L/min), and respiratory quotient (RQ) will all be collected using a COSMED K5 portable metabolic measurement system These measures are used for calculating kCal/min = (\[1.1 \* RQ\] + 3.9) \* VO2

600 Meter Course - Usual Wheelchair, Timed (seconds)

Time Frame: up to 4 weeks after enrollment

The distance of 600 meters is used clinically to assess community ambulation ability and can be used to determine if a power wheelchair is needed. The 600 meter course will include several turns, carpeting, and starting/stopping the wheelchair. Participants will be instructed to complete the course at a comfortable pace and will be timed (s).

600 Meter Course - Multispeed Wheelchair, Timed (seconds)

Time Frame: up to 4 weeks after enrollment

The distance of 600 meters is used clinically to assess community ambulation ability and can be used to determine if a power wheelchair is needed. The 600 meter course will include several turns, carpeting, and starting/stopping the wheelchair. Participants will be instructed to complete the course at a comfortable pace and will be timed (s).

QUEST 2.0 - Usual Wheelchair

Time Frame: up to 4 weeks after enrollment

The QUEST evaluates how satisfied one is with an assistive device.

QUEST 2.0 - Multispeed Wheelchair

Time Frame: up to 4 weeks after enrollment

The QUEST evaluates how satisfied one is with an assistive device.

20 Meter Push Test - level surface, Gear Ratio 3:2

Time Frame: up to 4 weeks after enrollment

Individuals self-propel a wheelchair 20 meters at their chosen pace

20 Meter Push Test - uphill, Gear Ratio 2:3

Time Frame: up to 4 weeks after enrollment

Individuals self-propel a wheelchair 20 meters at their chosen pace

20 Meter Push Test - Carpet, Gear Ratio 2:3

Time Frame: up to 4 weeks after enrollment

Individuals self-propel a wheelchair 20 meters at their chosen pace

6 Minute Push Test - Gear Ratio 2:3, Temporal/Spatial

Time Frame: up to 4 weeks after enrollment

Distance (m) and number of pushes will be collected during this test.

Wheelchair Skills Test Version 5.2 - Usual Wheelchair

Time Frame: up to 4 weeks after enrollment

The WST is used for objective evaluation of manual wheelchair skills. It includes 32 skills that are rates advanced pass/highly proficient (3 points), pass (2 points), pass with difficulty (1 point), or fail (0 points). The WST covers a wide variety of skills that manual wheelchair users experience in everyday life including inclines, side slopes, soft surface, thresholds, gaps, curbs, obstacle avoidance, and wheelies.

6 Minute Push Test - Usual Wheelchair, Temporal/Spatial

Time Frame: up to 4 weeks after enrollment

Distance (m) and number of pushes will be collected during this test.

6 Minute Push Test - Usual Wheelchair, Metabolic (kCal/min)

Time Frame: up to 4 weeks after enrollment

Oxygen Uptake (VO2: L/min), Carbon dioxide production (VCO2: L/min), and respiratory quotient (RQ) will all be collected using a COSMED K5 portable metabolic measurement system These measures are used for calculating kCal/min = (\[1.1 \* RQ\] + 3.9) \* VO2

6 Minute Push Test - Gear Ratio 2:3, Metabolic (kCal/min)

Time Frame: up to 4 weeks after enrollment

Oxygen Uptake (VO2: L/min), Carbon dioxide production (VCO2: L/min), and respiratory quotient (RQ) will all be collected using a COSMED K5 portable metabolic measurement system These measures are used for calculating kCal/min = (\[1.1 \* RQ\] + 3.9) \* VO2

6 Minute Push Test - Gear Ratio 3:2, Metabolic (kCal/min)

Time Frame: up to 4 weeks after enrollment

Oxygen Uptake (VO2: L/min), Carbon dioxide production (VCO2: L/min), and respiratory quotient (RQ) will all be collected using a COSMED K5 portable metabolic measurement system These measures are used for calculating kCal/min = (\[1.1 \* RQ\] + 3.9) \* VO2

Wheelchair Skills Test Version 5.2 - Multispeed Wheelchair

Time Frame: up to 4 weeks after enrollment

The WST is used for objective evaluation of manual wheelchair skills. It includes 32 skills that are rates advanced pass/highly proficient (3 points), pass (2 points), pass with difficulty (1 point), or fail (0 points). The WST covers a wide variety of skills that manual wheelchair users experience in everyday life including inclines, side slopes, soft surface, thresholds, gaps, curbs, obstacle avoidance, and wheelies.

Mobility-Related ADL - Usual Wheelchair, Independency

Time Frame: up to 4 weeks after enrollment

This is a standardized, timed circuit of simulated mobility-related ADL tasks to simulate a morning ADL routine. All ICF activity-based measures of function in a wheelchair. Independence for tasks will be scored using the Function Everyday with a Wheelchair Capacity scoring from 0 (dependent) to 3 (independent).

Mobility-Related ADL - Multispeed Wheelchair, Timed (seconds)

Time Frame: up to 4 weeks after enrollment

This is a standardized, timed circuit of simulated mobility-related ADL tasks to simulate a morning ADL routine.

Mobility-Related ADL - Multispeed Wheelchair, Independency

Time Frame: up to 4 weeks after enrollment

This is a standardized, timed circuit of simulated mobility-related ADL tasks to simulate a morning ADL routine. All ICF activity-based measures of function in a wheelchair. Independence for tasks will be scored using the Function Everyday with a Wheelchair Capacity scoring from 0 (dependent) to 3 (independent).

Study Sites (2)

Loading locations...

Similar Trials