跳至主要内容
临床试验/NCT00817115
NCT00817115Unknown1 期

Trial to Determine Non-inferiority of Exposure Dose Reduction and Diagnostic Performance of Region-of-Interest Fluoroscopy (X-ray Fovea Imaging) Compared to Standard Fluoroscopy in Patients Undergoing Cardiac Interventional Procedures

Sunnybrook Health Sciences Centre2 个研究点 分布在 1 个国家目标入组 75 人开始时间: 2009年2月最近更新:
适应症

试验速览

阶段
1 期
入组人数
75
试验地点
2
主要终点
X-ray exposure area product, primary and scatter radiation to patient and interventionist and procedure and irradiation time for interventions performed without and with region-of-interest imaging (control and experimental arms, respectively).

研究概览

简要总结

The aim of the proposed study is to compare the exposure dose and diagnostic performance of region-of-interest fluoroscopy compared to standard fluoroscopy in patients and interventionists during cardiac interventional procedures. It is hypothesized that systematic application of x-ray attenuation will significantly reduce the radiation exposure of the interventional procedure while maintaining image quality, thereby decreasing risk to the patient.

详细描述

X-ray catheterization is used to guide minimally invasive procedures including percutaneous coronary interventions (PCIs), involving diffuse and multiple vessel disease and total chronic occlusion as well as electrophysiology (EP) procedures. While the medical benefit to patients outweighs the procedural risk, long fluoroscopy times associated with complex interventions have resulted in acute radiation injuries to patients. Radiation induced cancers have also become a concern in younger patient populations. With the increased number, diversity and complexity of the interventions performed, there has been a growing interest in reducing the long-term exposure risk to medical personnel (interventionists).

Conventional methods to reduce in radiation exposure, however, impact and often degrade diagnostic image quality. Catheterization procedures focus on a small portion of the anatomy forming the central region of the image with the periphery providing contextual information. Thus, decreasing the image quality in periphery can provide an overall exposure reduction to patients and interventionists without impacting on diagnosis. This can be achieved by introducing a pre-patient region-of-interest (ROI) attenuator that collimates the primary x-ray beam, reducing exposure to peripheral regions and decreasing integral radiation to the patient and scatter radiation to the interventionist.

The goal of this study is to investigate the exposure dose reduction provided by ROI imaging to patients and interventionists undergoing catheterization and to examine the feasibility of using the ROI attenuator in routine clinical practice for future integration into commercial x-ray imaging systems. The aim is to obtain exposure dose data and cardiac angiography images from subjects undergoing routine interventional procedures performed with and without ROI attenuation (experimental and control groups, respectively). For the experimental group, the interventionists performing the procedure will determine the appropriate application of the ROI attenuator and the duration of its use on specific patient lesions. An internal pilot study will be initially conducted on approximately 30 patients (15 per group) to obtain estimates on patient and operator dose reduction and variability. The on-going clinical trial will then be performed on an additional 40 patients (where the final protocol procedures and recruitment will be refined based on results from the pilot study).

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • The subject is greater than 18 years of age.
  • The subject is currently planned for conventional cardiac interventional procedures (i.e. catheterization, percutaneous coronary intervention (PCI), electrophysiology (EP) ablations and procedures) as specified by his/her physician.
  • The subject is able and willing to comply with study procedures, and signed and dated informed consent is obtained.

排除标准

  • The subject is pregnant or trying to become pregnant.
  • The subject requires urgent/emergent cardiac catheterization, PCI, and/or EP procedures as per treating physician.
  • The subject has been previously included in the study.

结局指标

主要结局

X-ray exposure area product, primary and scatter radiation to patient and interventionist and procedure and irradiation time for interventions performed without and with region-of-interest imaging (control and experimental arms, respectively).

时间窗: The outcome measure will be recorded per patient procedure. A comparison between control and experimental arms will be conducted after the pilot study (at ~1 to 2 months) and at end the full study (at ~4 to 6 months).

次要结局

  • Quality and diagnostic benefit of images obtained without and with the region-of-interest imaging.(Retrospective expert comparison of images from patient procedures (between control and experimental arms) will occur within 1 to 3 months after the completion of the pilot study and the full study.)

研究者

申办方类型
Other

研究点 (2)

Loading locations...