The Impact of Ultrasound Use in Central Block Applications in Obstetric Anesthesia
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 100
- 试验地点
- 1
- 主要终点
- Investigating The Skin-to-subdural/epidural Distance and Needle Depth in Central Block applications
研究概览
简要总结
This study aimed to evaluate the use of ultrasound in obstetric anesthesia, specifically for measuring epidural and intrathecal distances in pregnant women undergoing cesarean section. The relationship between skin-subdural distance (Ultrasound depth) and needle depth was assessed, and the accuracy of ultrasound in determining needle entry site, needle distance, trial attempts, and block success was examined. Additionally, complications such as paresthesia, lower back pain, and postoperative headache were queried and recorded.
详细描述
Obstetric anesthesia generally posed low risks; however, the difficulty of the procedure and the potential complications increased due to the anatomical and physiological changes associated with pregnancy.
The aim of study was to measure epidural and intrathecal distances in pregnant women undergoing cesarean sections and to evaluate the relationship between the skin-subdural distance (Ultrasound depth) and needle depth. The investigator assessed the accuracy of Ultrasound in determining the needle entry site, needle distance (measured at the site where cerebrospinal fluid flow occurred or where there was a loss of resistance in the epidural space), trial numbers, and block success. Additionally, occurrences of paresthesia and lower back pain during the procedure, as well as postoperative headaches following dural puncture, were queried and recorded.
After obtaining approval from the Ege University Faculty of Medicine Ethical Committee, the study was prospectively conducted in the operating room of the Department of Obstetrics and Gynecology at Ege University Hospital. One hundred pregnant women classified as ASA I-II, between 37-42 gestational weeks, undergoing elective cesarean sections with neuraxial blocks (spinal and/or epidural), were included after obtaining their consent.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 性别
- Female
- 接受健康志愿者
- 否
入选标准
- •Patients classified as ASA I-II
- •Patients at 37-42 gestational weeks
- •Patients scheduled for elective cesarean section under neuraxial block (spinal and/or epidural)
排除标准
- •Patients who did not consent to spinal anesthesia
- •Patients with contraindications for regional anesthesia (coagulopathy, local or systemic infection)
- •Emergency patients
结局指标
主要结局
Investigating The Skin-to-subdural/epidural Distance and Needle Depth in Central Block applications
时间窗: Preoperative
The Use of Ultrasonography in Central Block Applications in Obstetric Patients
次要结局
未报告次要终点
研究者
Sukran Ozbebek
Anesthesiologist
Ege University