Prospective Randomised Study Comparing Efficacy of Treatment Coronary In-stent Restenosis Using Drug Eluting Paclitaxel-coated Balloon and Drug Eluting Stent With Everolimus.

University Hospital Ostrava2 个研究点 分布在 1 个国家目标入组 199 人开始时间: 2012年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
199
试验地点
2
主要终点
Late lumen loss

研究概览

简要总结

The purpose of this study is to compare efficacy of coronary in-stent restenosis therapy using drug eluting paclitaxel-coated balloon catheters with the latest generation of drug eluting stents releasing everolimus.

详细描述

In-stent restenosis after coronary angioplasty is currently one of the main limitations of this method, leading to a recurrence of exertional angina pectoris or manifesting as acute coronary syndrome. Histopathologic substrate of in-stent restenosis is neointimal hyperplasia.

Repeated plain balloon angioplasty or using cutting balloon catheters in the treatment of in-stent restenosis does not achieve satisfactory results. Brachytherapy, used in the past, it has also abandoned. The current treatment of in-stent restenosis is the use of drug eluting stents. Local drug released from these stents prevents new neointimal hyperplasia.This treatment carries the risk of late thrombosis (due to delayed neoendotelization) the stent struts and requires rigorous long-term dual antiplatelet therapy with the risk of bleeding complications. The drug-coated balloon catheters provide short-term penetration of the active substance into the vascular wall, leading to the inhibition of hyperproliferation vascular smooth muscle cells, but due to short-term effect they do not affect negatively stent struts neoendotelization. Comparable effects of in-stent restenosis therapy using paclitaxel releasing balloons was demonstrated in comparison with paclitaxel releasing stents, however, the development of drug eluting stents meanwhile progressed. The aim of our study is to compare efficacy of coronary in-stent restenosis therapy using drug eluting paclitaxel-coated balloon catheters with the latest generation of drug eluting stents releasing everolimus. Primary endpoint of our study is late lumen loss, because it represents accurate angiographic parameter predicting the need for repeat revascularisation and thus the clinical benefit for the patient.

The 3rd observational, non-randomised arm compares the treatment with seal-wing paclitaxel-eluting balloon with two randomised arms (PEB vs. EES).

3-year long term clinical follow-up of iopromide-coated PEB and EES arms was performed. All clinical MACE (CV death, AMI and TVR) were recorded.

Subanalysis of seal-wing PEB arm comparrng the treatment of BMS and DES-ISR was added.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Double (Participant, Outcomes Assessor)

盲法说明

double blind

入排标准

年龄范围
20 Years 至 90 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • history of percutaneous coronary intervention with stent placement
  • verified coronary in-stent restenosis suitable for percutaneous re-intervention
  • signed informed consent

排除标准

  • contraindication to long term dual antiplatelet therapy
  • increased risk of bleeding
  • known generalized malignancy
  • pregnancy

结局指标

主要结局

Late lumen loss

时间窗: 12 month

Late loss was defined as the minimal vessel lumen diameter immediately after the procedure minus the lumen diameter at angiographic follow-up

次要结局

  • Major Adverse Cardiac Events(12 month)

研究者

发起方
University Hospital Ostrava
申办方类型
Other
责任方
Sponsor