临床试验/NCT04875442
NCT04875442撤回不适用

Safety and Performance Study of the Electroencephalographic Recording Device and Sound Emissions MemoWave Aimed at Increasing Slow Brain Waves During Sleep to Improve Memory Consolidation in Subjects With Mild Cognitive Impairment

BioSerenity1 个研究点 分布在 1 个国家开始时间: 2023年10月30日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
撤回
发起方
BioSerenity
试验地点
1
主要终点
accuracy of Electroencephalography signals of Memowave

研究概览

简要总结

Safety and performance study of the MemoWave electroencephalographic and sound recording device to increase slow brain waves during sleep to improve memory consolidation in subjects with mild cognitive impairment

详细描述

24 subjects aged between 40 and 85 years, presenting a mild cognitive disorder of the amnesic type (ie a memory complaint, a Mini Mental State ≥ 24 and a score ≤26 on free recall or ≤45 / 48 on total recall of the RLRI16 test) will be included;

Each patient spends 3 polysomnography nights at hospital: 1 night of habituation without Memowave device and next 2 nights with Memovave.

The device emits sounds to increase slow brain waves but Memowave emits sounds during only one of the two nights of test (night placebo vs night "verum"). The attribution of the night is randomized.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Other
盲法
Triple (Participant, Investigator, Outcomes Assessor)

入排标准

年龄范围
40 Years 至 85 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Subject presenting a mild cognitive disorder of the amnesic type, defined by a memory complaint, a Mini Mental State ≥ 24 and a score ≤26 on free recall or ≤45 / 48 on total recall) of the RLRI16 episodic verbal memory test
  • •At least 7 years of schooling

排除标准

  • •Severe psychiatric pathology
  • •Known neurological pathology
  • •High risk of apnea syndrome defined by at least 2 positive categories (each with a score ≥2) on the Berlin Questionnaire for Apnea Syndrome Screening
  • •High risk of behavioral disorder in REM sleep defined by an RBDSQ score>
  • •Taking sleeping pills or antidepressants
  • •Severe heart disease or unbalanced diabetes

研究组 & 干预措施

Memowave emitting sound

Experimental

Patients worn Memowave during one night, and the device emits sounds to increase slow brain signals

干预措施: Memowave emitting sounds (Device)

Memowave not emitting sound

Placebo Comparator

Patients worn Memowave during one night, and the device doesn't emit sounds

干预措施: Memowave not emitting sounds (Device)

结局指标

主要结局

accuracy of Electroencephalography signals of Memowave

时间窗: 3 days

number of slow waves of Memomave divided by number of slow waves of Gold standard should be under 1

次要结局

  • efficiency on mnesic consolidation(3 days)
  • Quality of the sleep(3 days)