跳至主要内容
临床试验/NCT01999751
NCT01999751已完成不适用

SMDC CRM-MRI Prospective Case Series

Essentia Health1 个研究点 分布在 1 个国家目标入组 124 人开始时间: 2012年10月最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
124
试验地点
1
主要终点
Pacing threshold increase

研究概览

简要总结

This study is a prospective, non-randomized, unblinded case series of patients with permanent pacemakers and implantable cardioverter-defibrillators undergoing medically-required magnetic resonance imaging (MRI) scanning, at St. Mary's Medical Center, Essentia Health. Patients will be enrolled over a 60-month period and followed for 12 months, with data collected to evaluate the study's primary endpoint, change in pacing thresholds over time, as well as a series of secondary endpoints, including: adverse events, symptoms, need to make pacemaker programming changes, and possible artifacts created by the pacemaker systems on the MRI scans. This study will allow for carefully monitoring of the safety MRI scanning in this population and improve practice models and protocols in the future.

详细描述

General Approach: This study is a prospective, non-randomized, unblinded case series of patients with permanent pacemakers or implantable cardioverter-defibrillators (ICDs) undergoing medically-required MRI scanning, followed for a 12 month period. MRI scanning will be performed using accepted, standard protocols using FDA-approved equipment.

Methods and Materials: Patients will be enrolled over a 60-month period by the Principal Investigator (PI) and/or Sub-Investigator (Sub-I), at the Regional Heart Center, located at St. Mary's Medical Center, Essentia Health, Duluth, MN, during evaluations for medically-required MRI scanning. Eligible patients includes any person with a permanent pacemaker or ICD implanted for at least 6 weeks, referred for a medically-required MRI scan by a physician not participating in the trial. ICD generators must have been market released after 2001. Both pacemaker dependent and non-dependent patients are eligible. The primary endpoint is any change greater than 1 V at a pulse width of 0.5 ms in a pacemaker or ICD lead at any time within 12 months of the MRI scan.

On the day of the MRI scan, the pacemaker or ICD will be interrogated and programmed per usual practice at Essentia Health for patients undergoing an MRI scan with device in place. Three separate baseline capture threshold measurements (V) will be obtained at a fixed pulse width of 0.5 msec. Three separate baseline measurements will also be made of lead pacing impedances (Ohms) and sensed P- or R-waves (mV) using programmer default methods. Histograms will be cleared. Leads will be programmed to bipolar modality. If the patient is not device dependent, the device will be programmed to ODO/OVO/OAO mode (monitor only) if available, otherwise it will be reprogrammed to DDI or VVI mode with a lower rate of 40 bpm with pacing outputs programmed to subthreshold levels in all leads. If the participant is device dependent, the device will be programmed to an asynchronous pacing modality (DOO/VOO) with maximum pacing output. If the patient has an ICD, therapies will be disabled. The attending investigator may alter the pacing modality during the course of the scan if he or she deems it necessary to maximize patient safety or comfort. Rate responsiveness, any rate enhancements including Ventricular Rate Regulation mode, and magnet mode will be turned off.

During MRI scanning, resuscitation equipment will be available. If the participant is pacemaker dependent, the study PI or sub-I must be in the MRI suite during the scan. If the participant is not pacemaker dependent, then a pacemaker nurse will be in the MRI suite to perform pre- and post-checks, and an electrophysiologist will be available in the building for questions and troubleshooting. Patients will be asked to report all symptoms including: palpitations; pain; heat or warmth sensation; device movement; or light-headedness.

Scans will be performed using usual protocols with standard peak Specific Absorption Rate (SAR) limitations for the scan. The MRI scans will be evaluated for any artifact created by the pacemaker system. During the scan, continuous electrocardiographic and pulse oxymetry with waveform monitoring will be performed using usual protocols. Following the scan, repeat thresholds will be performed for each lead and histograms will be obtained. Three separate capture threshold measurements (V) will be obtained immediately after the patient leaves the scanner room at a fixed pulse width of 0.5 msec. Three separate measurements will also be made immediately following the scan of the lead pacing impedances (Ohms) and sensed P- or R-waves (mV) using programmer default methods. Participants who are pacemaker dependent will undergo a one-hour post-scan check using the same threshold protocol. These one-hour post scan measurements will be performed either in the pacemaker clinic if the patient is an outpatient or in the hospital if the patient is an inpatient. Any stored events detected on the device as electromagnetic interference (EMI) artifact during the scan may be retrieved and stored to diskette for later analysis. The pacemaker or ICD will be reprogrammed to original settings prior to discharge from the MRI suite unless the attending investigator deems it necessary to alter device setting to maximize patient safety or comfort. If the patient has an ICD, the capacitor will be reformed and charge time noted prior to dismissal from the MRI suite.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Permanent Pacemaker or ICD implanted for at least 6 weeks
  • Referred for medically-required MRI scan
  • Age greater than or equal to 18 years

排除标准

  • ICD market released before 2001 including GDT Ventak-AV, GDT MINI-II, GDT MINI-IV, GDT MINI-III, GDT Prizm, GDT Prizm-2 and MDT GEM-I series
  • Epicardial lead or subcutaneous array
  • Device has reached elective replacement indicator (ERI) or end of life (EOL)
  • Other usual contraindications to MRI scanning
  • Known or suspected lead fracture or abandoned lead
  • Pacemaker dependent patients with an ICD that cannot be programmed to asynchronous pacing (DOO/VOO)
  • Clinical factors that are deemed by the PI or Sub-I to increase the participant's risk above an acceptable clinical threshold

结局指标

主要结局

Pacing threshold increase

时间窗: 12 months

Any change greater than 1 V at a pulse width of 0.5 msec in a pacemaker or implantable cardioverter-defibrillator lead at any time within 12 months of the MRI scan

次要结局

  • Ectopy(1 hour)
  • Pacemaker reprogramming(12 months)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Michael Mollerus

Physician

Essentia Health

研究点 (1)

Loading locations...

相似试验