跳至主要内容
临床试验/NCT06673992
NCT06673992已完成不适用

Evaluation of Corneal Irregular Astigmatism and Visual Quality Following Bilateral Sequential Small Incision Lenticule Extraction (SMILE) and Laser Subepithelial Keratomileusis (LASEK): A Six-Year Comparative Study

Shanghai 10th People's Hospital1 个研究点 分布在 1 个国家目标入组 71 人开始时间: 2017年10月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
71
试验地点
1
主要终点
Corneal Irregular Astigmatism

研究概览

简要总结

To compare the corneal spherical component (SC), regular astigmatism (RA), irregular astigmatism (IA, including Asymmetry and Irregularity) and visual quality six years after small incision lenticule extraction (SMILE) and laser subepithelial keratomileusis (LASEK) for mild to moderate myopia.

研究设计

研究类型
Observational
观察模型
Case Control
时间视角
Retrospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • (1) patients aged over 18 years; (2) absence of corneal, ocular, or systemic diseases; (3) stable refractive diopter maintained for the past 2 years with a change of ± 0.50 diopter; (4) discontinuation of soft contact lens wear for at least 2 weeks and rigid contact lenses for at least 4 weeks prior to surgery; (5) preoperative manifest refraction spherical equivalent (MRSE) less than -6.00 diopter (D)

排除标准

  • A history of moderate to severe dry eye as well as any ocular or systemic disease that would contraindicate laser refractive surgery

结局指标

主要结局

Corneal Irregular Astigmatism

时间窗: preoperative and 6 years postoperatively

The swept-source anterior segment OCT (CASIA SS-1000) was utilized to acquire corneal topography measurements. In the Corneal Map mode, 16 radial cross-sectional images (512 telecentric+A-scans) were obtained within a duration of 0.3 s for each measurement. The analysis program identified and digitized the anterior and posterior corneal surfaces to evaluate distributions of corneal power and corneal height for both the anterior and posterior corneal surfaces. The unit of Corneal Irregular Astigmatism is D.

wavefront aberration

时间窗: preoperative and 6 years postoperatively

The wavefront aberrations were measured and analyzed for 6-mm pupil diameter with a Zywave aberrometer using a Hartmann-Shack sensor (Bausch \& Lomb, US). The absolute Zernike coefficients including vertical trefoil, horizontal trefoil, vertical coma, horizontal coma, spherical aberration, and total higher-order aberrations (tHOAs) were examined. The unit of wavefront aberration is um.

次要结局

未报告次要终点

研究者

发起方
Shanghai 10th People's Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Hua Li

resident doctor

Shanghai 10th People's Hospital

研究点 (1)

Loading locations...

相似试验