MedPath

Comparison of a Novel Non-diffractive Extended Depth of Focus Intraocular Lens (IOL) and a Trifocal IOL

Completed
Conditions
Cataract
Quality of Life
Intraocular Lens
Registration Number
NCT05262504
Lead Sponsor
Baskent University Ankara Hospital
Brief Summary

The purpose of this study is to compare visual performance and quality of life (QOL) following bilateral implantation of a novel non-diffractive extended depth-of-focus (EDOF) intraocular lens (IOL) (AcrySof® IQ Vivity, Alcon, TX, USA) and a trifocal IOL (Acrysof® IQ PanOptix, Alcon, Fort Worth, TX) in a prospective comparative interventional case series.

Detailed Description

Developments in cataract surgical devices and intraocular lenses (IOL) increased patient expectations and changed the practice patterns in ophthalmology. Nowadays, cataract surgery is considered as a refractive surgery. With multifocal IOLs, spectacle independence can be achieved with a good distance, intermediate and near visual acuity. This is associated with increased quality of life after cataract surgery.The most important disadvantages of multifocal IOLs are loss of contrast sensitivity and photic phenomena such as glare and halo. Although multifocal IOLs are more frequently associated with photic disturbances than monofocal IOLs, the trifocal IOLs have improved performance in photic phenomena when compared to bifocal IOLs. Recently, a new technology known as extended depth of focus (EDOF) IOLs have been developed. These lenses create a single elongated focal point to enhance the depth of focus, improving intermediate vision without compromising distance vision. Although EDOF IOLs provide better intermediate distance vision when compared to monofocal IOLs, near vision is not as good as trifocal IOLs. The most important advantage provided by the EDOF technology is lower rate of photic disturbances than trifocal IOL designs. The aim of this study was to compare the visual performance and patient-reported quality of life (QOL) outcomes following bilateral implantation of a novel non-diffractive wavefront shaping EDOF IOL (AcrySof® IQ Vivity, Alcon Research, TX, USA) and a trifocal IOL (AcrySof® IQ PanOptix, Alcon Laboratories, Fort Worth, TX).

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
52
Inclusion Criteria
  • Cataract patients scheduled for surgery who are interested in spectacle independence.
  • Bilateral cataract with plan of bilateral sequential cataract surgery.
  • Adult patients older than 18 years of age
  • Normal cognitive function, able to understand advantages and disadvantages associated with different types of IOLs.
Exclusion Criteria
  • Ocular diseases other than cataract including irregular astigmatism, diabetic retinopathy, age-related macular degeneration or any other retinal diseases, severe dry eye, glaucoma, amblyopia, uveitis, pseudoexfoliation syndrome, abnormal pupillary function, history of intraocular or corneal surgery, congenital eye abnormalities, or eye trauma.
  • Patients with high myopia with axial length (AL) ≥ 26,5 mm and high hyperopia (AL ≤ 21.5 mm)
  • Lifestyle and work-related factors requiring sharp near or distance vision
  • Patients with unrealistic visual expectations.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Defocus-curvespostoperative third month

The monocular defocus curves were evaluated under photopic conditions using defocusing lenses from +0.50 D to -4.00 D in 0.50 D steps. The measurements were performed by adding the lenses to the CDVA.

Postoperative visual acuity with or without spectacle correction at near, far and intermediate distancespostoperative third month

uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), distance corrected intermediate visual acuity (DCIVA), distance corrected near visual acuity (DCNVA)

Quality of vision / dysphotopsiapostoperative third month

Dysphotopsia was assessed by the Quality of Vision (QoV) questionnaire developed by McAlinden et al. The QoV is a validated Rasch-adjusted questionnaire in which patients are asked to rate specific dysphotopsia items depicted in standard photographs. Patients score each item (0, 1, 2, or 3) in relation to how frequent, severe, and bothersome their symptoms are (30 items in total). Lower QoV scores indicate a better quality of vision.

Vision-related quality of life (QOL)postoperative third month

The vision-related QOL was assessed three months after the surgery by the VF-14 QOL questionnaire that was administered face-to-face by a trained researcher (İK). The grading scale was as follows: 0, no difficulty; 1, a little difficulty; 2, moderate difficulty; 3, quite difficult; 4, impossible to perform. Special care was taken not to influence the patients and to ensure that each question was fully understood.

Contrast sensitivitypostoperative third month

Monocular and binocular contrast sensitivity was assessed with the Pelli-Robson chart under photopic conditions at 3 meters.

Reading speedpostoperative third month

Reading speed was measured using the validated Turkish version of the MNREAD chart in photopic illumination conditions. It was recorded as number of words read by the patient in one minute (words per minute-wpm).

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Baskent University Faculty of Medicine

🇹🇷

Ankara, Turkey

Baskent University Faculty of Medicine
🇹🇷Ankara, Turkey

MedPath

Empowering clinical research with data-driven insights and AI-powered tools.