Skip to main content
Clinical Trials/NCT06034093
NCT06034093CompletedNot Applicable

Real-time AI-assisted Muscle Ultrasound for Monitoring Muscle Mass Reduction in Intensive Care Unit Patients

Oxford University Clinical Research Unit, Vietnam2 sites in 1 country254 target enrollmentStarted: June 1, 2020Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
254
Locations
2
Primary Endpoint
Reproducibility of RFCSA measurements

Study Overview

Brief Summary

This study aims to investigate the feasibility of using a real-time artificial intelligent (AI)-assisted tool for Rectus Femoris cross sectional area measurement from muscle ultrasound to improve reliability, reduce inter- and intra-observer variability and reduce operator time spent on ultrasound examination

Detailed Description

This project proposes to develop computational methods to automatically analyze conventional 2D muscle ultrasound images in real time to assist operators circumvent achieve high quality reproducible views and measurements specifically for Rectus Femoris muscle.

Study design: This is a prospective observational study to test the reliability of AI-assisted muscle ultrasound at the patient's bedside compared to standard RFCSA ultrasound. All measurements will be performed in adult patients with severe tetanus (Ablett Grade 3 or 4) admitted to the Adult ICU at HTD expected to stay at least 5 days. All patients are on mechanical ventilation, muscle relaxation and neuromuscular blockers following the Ministry of Health guidelines.

Study procedures: Three ultrasound examinations will be carried out according to a standard operating procedure where patients are in the supine position with the leg in neutral rotation. Measurements will be taken using 12L-RS linear probe, Venue Go ultrasound machine (General Electric Healthcare, London, UK).

Statistical analysis

Study will compare the intra- and interobserver variability of measurements and examination duration. All statistical analysis was performed with R version 4.0.4.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Supportive Care
Masking
None

Eligibility Criteria

Ages
16 Years to — (Child, Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Age ≥16 years
  • Written informed consent
  • Staff and equipment available for ultrasound
  • Admitted to Viet Anh Ward ICU with a diagnosis of meningitis or encephalitis or Ablett Grade 3 or 4 tetanus
  • Within 72 hours of ICU admission
  • Duration of ICU stay expected at least 5 days

Exclusion Criteria

  • Informed consent not given
  • Contraindication to ultrasound scan

Outcomes

Primary Outcomes

Reproducibility of RFCSA measurements

Time Frame: during the study procedure

In this trial, the users are randomly assigned to scan muscle ultrasound with and without AI-assisted software to measure the size of the Rectus Femoris muscle. The investigators will compare the reliability and agreement metrics of the RF measurement

Secondary Outcomes

  • Time spent on ultrasound examination(during the study procedure)

Investigators

Sponsor Class
Other
Responsible Party
Sponsor

Study Sites (2)

Loading locations...

Similar Trials