Study on the Difference of Preoperative Related Parameters in Children With or Without Microcornea Within Less Than One Year Old
- Conditions
- Microcornea Within One Year of Age
- Interventions
- Device: Collect ocular biological parameters including age, corneal diameter, eye axis, intraocular pressure, steep&flat axis of corneal curvature, corneal thickness, lens thickness, anterior chamber depth
- Registration Number
- NCT04852341
- Lead Sponsor
- Wenzhou Medical University
- Brief Summary
This subject is mainly to study difference of Congenital cataract preoperative related parameters in children with or without Microcornea within Less than one year old. A total of 186 eyes of 117 people were collected with relevant ocular biological parameters, including age, horizontal diameter of the cornea, Eye axis, intraocular pressure, steep axis of corneal curvature, flat axis of corneal curvature, corneal thickness, lens thickness, anterior chamber depth. At present, because the definition of patients with small cornea is not clear enough, the study subjects are divided into 4 groups according to the horizontal corneal diameter of 9.0mm, 9.5mm, and 10.0mm, namely ≤9.0mm group, 9\~9.5mm group, 9.5\~10.0mm group and The \>10.0mm group compares the differences between each other, and tries to provide a reference for the diagnosis of children with small cornea at a young age.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 117
- Congenital cataract children with or without Microcornea within Less than one year old
- Complete collection of eye biological parameters before the first-stage Congenital cataract surgery
- The nutritional status and development of the included subjects have no obvious defects
- congenital persistent pupilary membrane
- lens sublaxation or lens dislocotion
- Marfan syndrome
- Down's Syndrome
- Peters abnormality
- Fevr
- history of obvious eye trauma
- obvious macula
- long-term (local or systemic) use of glucocorticoids.
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Corneal horizontal diameter 9.50mm~10.00mm group Collect ocular biological parameters including age, corneal diameter, eye axis, intraocular pressure, steep&flat axis of corneal curvature, corneal thickness, lens thickness, anterior chamber depth - Corneal horizontal diameter ≤9.00mm group Collect ocular biological parameters including age, corneal diameter, eye axis, intraocular pressure, steep&flat axis of corneal curvature, corneal thickness, lens thickness, anterior chamber depth - Corneal horizontal diameter 9.00mm~9.50mm group Collect ocular biological parameters including age, corneal diameter, eye axis, intraocular pressure, steep&flat axis of corneal curvature, corneal thickness, lens thickness, anterior chamber depth - Corneal horizontal diameter >10.00mm group Collect ocular biological parameters including age, corneal diameter, eye axis, intraocular pressure, steep&flat axis of corneal curvature, corneal thickness, lens thickness, anterior chamber depth -
- Primary Outcome Measures
Name Time Method horizontal diameter of the cornea 2015.5.1-2020.12.1 Use a ruler to measure during surgery
- Secondary Outcome Measures
Name Time Method steep axis of corneal curvature 2015.5.1-2020.12.1 Handheld eye curvature measuring instrument
anterior chamber depth 2015.5.1-2020.12.1 SS-OCT
intraocular pressure 2015.5.1-2020.12.1 i care handheld tonometer
Eye axis 2015.5.1-2020.12.1 A-type ultrasonic measuring instrument
corneal thickness 2015.5.1-2020.12.1 Handheld corneal thickness measuring instrument
lens thickness 2015.5.1-2020.12.1 A-type ultrasonic measuring instrument
age 2015.5.1-2020.12.1 flat axis of corneal curvature 2015.5.1-2020.12.1 Handheld eye curvature measuring instrument
Trial Locations
- Locations (1)
Wenzhou Medical University
🇨🇳Hangzhou, Zhejiang, China