Skip to main content
Clinical Trials/NCT07663799
NCT07663799Not yet recruitingNot Applicable

Wearable Assessment of Thoracic, Cardiac Health and Exercise Performance Trial Prospective (WATCH-XP)

The University of Hong Kong1 site in 1 country20 target enrollmentStarted: August 1, 2026Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Not yet recruiting
Enrollment
20
Locations
1

Study Overview

Brief Summary

Wearable health technology, particularly smartwatches, has revolutionized personal health monitoring by enabling continuous, non-invasive tracking of various physiological parameters. The potential applications of these devices in cardiology are extensive, but it is crucial to validate their accuracy against established medical-grade devices.

The Apple Watch Series 9 (Apple, USA) exemplifies the capabilities of modern smartwatches, offering a wide range of health tracking features. These include heart rate monitoring, detection of irregular heart rhythms suggestive of atrial fibrillation, electrocardiogram recording, blood oxygen level measurement, and comprehensive mobility metrics (including VO2 max, six-minute walk distance, walking speed, step length, double support time, and walking asymmetry). Many of these parameters are highly relevant for cardiovascular patients, potentially aiding in disease progression monitoring and adverse event prediction. However, there is a lack of comprehensive validation studies for these devices in specific cardiovascular disease populations.

This investigator-initiated, prospective observational study will consist of two phases: a training phase which involves 50 participants and a prospective validation phase which involves 20 participants. The study aims to validate smartwatch-based assessments using medical-grade devices and techniques. The study will focus on adult patients with congenital heart disease, pulmonary hypertension, heart failure, and coronary artery disease, as well as athletes undergoing cardiovascular assessment. By comparing smartwatch data with established clinical measurements, we seek to determine the reliability and potential clinical utility of these wearable devices in diverse cardiovascular contexts. Anonymized smartwatch data collected during the two phases will be published to a publicly registry to facilitate further research. This research will help bridge the gap between consumer-grade wearable technology and clinical practice in cardiology.

Detailed Description

This study is investigator-initiated, prospective observational study and will consist of two phases: a training phase and a prospective validation phase.

Training Phase (First Phase) 50 participants will undergo comprehensive baseline assessments and continuous physiological monitoring with the smartwatch. Data collected during this phase will be anonymized and exported to a public open-source training model.

At Visit 1 of the first phase, Comprehensive demographic and clinical data will be collected from each participant, Clinical Management System (CMS), Electronic Patient Record (ePR), and Clinical Data Analysis and Reporting System (CDARS) of the Hospital Authority in Hong Kong. This will include age, sex, height, weight, body mass index, and detailed medical history focusing on cardiovascular conditions. Information about current medications and smoking status will also be recorded. Additionally, participants will undergo a baseline clinical examination, including blood pressure measurement, heart rate, and a 12-lead electrocardiogram.

VO2max Participants will undergo a conventional cardiopulmonary exercise test (CPX) to determine their maximal oxygen uptake (VO2max) at Visit 1. This test will be conducted in a controlled clinical setting under the supervision of cardiologists. Participants will exercise on a treadmill while their respiratory gas exchange is measured using a metabolic cart. The exercise intensity will be gradually increased until the participant reaches volitional exhaustion or predetermined safety criteria are met. The highest oxygen uptake value achieved during the test will be recorded as the VO2max. Participant will concurrently be wearing the investigational smartwatch for pre- and post-SaO2 and VO2max assessment. This gold-standard measurement will serve as the reference for validating the smartwatch's continuous VO2max estimation.

6-Minute walk distance The 6-minute walk distance will be assessed in a hospital setting at Visit 2 of the first phase under the supervision of a research staff. Participants will be instructed to walk as far as possible in six minutes along a predetermined course, typically a straight hallway. The total distance walked will be measured and recorded. During the test, the research nurse will monitor the participant's heart rate, blood oxygen saturation, and perceived exertion at regular intervals. Participant will concurrently be wearing the investigational smartwatch for pre- and post-SaO2 and VO2max assessment.

Study Design

Study Type
Observational
Observational Model
Case Only
Time Perspective
Prospective

Eligibility Criteria

Ages
20 Years to 70 Years (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Age 20 to 70 years old
  • Ability to provide informed consent
  • History of the following cardiovascular conditions:
  • Adult congenital heart disease
  • Pulmonary hypertension
  • Heart failure
  • Coronary artery disease
  • Athletes undergoing cardiovascular assessment

Exclusion Criteria

  • Contraindication for undergoing physical exertion including cardio-pulmonary exercise testing (CPX) and 6-minute walk test (6MWT)
  • Pregnancy
  • Known allergy to components of the investigational product

Investigators

Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Wong Chun Ka

Clinical Assistant Professor

The University of Hong Kong

Study Sites (1)

Loading locations...

Similar Trials