跳至主要内容
临床试验/NCT07746167
NCT07746167招募中不适用

The Relationship Between Neurostimulation Intensity and Pupillary Dilation Reflex (PRD) in Healthy Volunteers

Children's National Research Institute1 个研究点 分布在 1 个国家目标入组 60 人开始时间: 2026年4月29日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
60
试验地点
1
主要终点
Pupillary Dilation Amplitude in Response to Increasing Neurostimulation Intensity Measured by AlgometRx Infrared Pupillometer

研究概览

简要总结

This a single site, observational study that will examine how the pupil responds to neurostimulation under different conditions in healthy adults. The objective is to measure pupillary dilation reflex (PRD) in response to increasing neurostimulation intensities using the AlgometRx device.

研究设计

研究类型
Observational
观察模型
Case Only
时间视角
Cross Sectional

入排标准

年龄范围
18 Years 至 60 Years(Adult)
性别
All
接受健康志愿者

入选标准

  • Age 18-60 years.
  • In good general health (self-reported).
  • Able and willing to provide written informed consent.

排除标准

  • Eye pathology that prevents accurate pupillometry.
  • Pregnancy (Self-Report)
  • Diagnosis of autoimmune disorders.
  • Diagnosis of any neuropathic disorder
  • Inability to complete questionnaires.

结局指标

主要结局

Pupillary Dilation Amplitude in Response to Increasing Neurostimulation Intensity Measured by AlgometRx Infrared Pupillometer

时间窗: Day 1

Pupillary dilation amplitude is defined as the maximum increase in pupil diameter from the pre-stimulus baseline, measured in millimeters (mm) using the AlgometRx infrared pupillometer. Pupil diameter is recorded before, during, and for 10 seconds following each 1-second stimulus. Amplitude is assessed at each stimulation intensity, beginning at 1.0 mA and increasing in 1 mA steps until participant perception, followed by measurements at 2 mA and 4 mA above the perception threshold, at each of three frequencies (5 Hz, 250 Hz, and 2000 Hz). Reported as the mean pupillary dilation amplitude in millimeters at each intensity and frequency combination.

次要结局

  • Baseline Pupil Diameter Variability During the Pre-Stimulation Period Measured by AlgometRx Infrared Pupillometer(Day 1)
  • Area Under the Pupillary Dilation Curve (AUC) Measured by AlgometRx Infrared Pupillometer(Day 1)
  • Difference in Pupillary Dilation Amplitude Between Ambient Lighting Conditions Measured by AlgometRx Infrared Pupillometer(Day 1)
  • Inter-Ocular Agreement in Pupillary Dilation Amplitude Measured by AlgometRx Binocular Handheld Attachment(Day 1)
  • Percentage of Participants With Successful Simultaneous Binocular Pupillary Recording Using the AlgometRx Binocular Handheld Attachment(Day 1)

研究者

发起方
Children's National Research Institute
申办方类型
Other
责任方
Principal Investigator
主要研究者

Julia Finkel

Professor of Anesthesiology and Pediatrics

Children's National Research Institute

研究点 (1)

Loading locations...

相似试验