Comparison Between Ultrasound-guided Out-of-plane Internal Jugular Vein and In-plane Supraclavicular Subclavian Vein Catheterization in Intensive Care Unit Patients-a Randomized Trial
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 250
- 试验地点
- 2
- 主要终点
- The overall access time
研究概览
简要总结
Patients were randomly divided into two groups: ultrasound-guided (US-guided) out-of-plane internal jugular vein (OOP-IJV) and in-plane supraclavicular subclavian vein (IP-SSV) catheterization.
For OOP-IJV cannulation, the transducer was placed to identify IJV in short-axis view. The needle was introduced at an angle of 60° to the skin surface, and advanced under real-time US guidance until visualizing the tip of the needle inside the vein.
For IP-SSV cannulation, a short-axis view of the IJV was obtained first. The probe was slid caudally following the IJV until getting the best long-axis view of the SCV. Using an in-plane approach, the needle was inserted at the base of the transducer at a 30° angle and advanced under the long axis under real-time US guidance targeting the SCV.
详细描述
Patients were randomly divided into two groups: ultrasound-guided (US-guided) out-of-plane internal jugular vein (OOP-IJV) and in-plane supraclavicular subclavian vein (IP-SSV) catheterization.
For OOP-IJV cannulation, the transducer was placed on transverse position over the patient's neck at the level of the cricoid cartilage to identify IJV and carotid artery (CA) in short-axis view. The vein was then centered on the screen. The skin puncture was made in the center of the US image using a needle attached to a syringe. The needle was introduced at an angle of 60° to the skin surface, perpendicular to the transducer, and advanced under real-time US guidance toward the IJV until visualizing the tip of the needle inside the vein.
For IP-SSV cannulation, a short-axis view of the IJV was obtained first. The probe was slid caudally following the IJV until the junction of the subclavian vein (SCV) and IJV was reached in the supraclavicular fossa. The probe was then turned slightly and tilted anteriorly to get the best long-axis view of the SCV and the brachiocephalic vein (BCV).
Using an in-plane approach, the needle attached to a syringe was inserted at the base of the transducer at a 30° angle and advanced strictly under the long axis of the US probe from lateral to medial. The needle point was then guided under real-time US guidance targeting the SCV.
In both groups, catheterization was done through Seldinger technique.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Basic Science
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 18 Years 至 90 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patients admitted in intensive care unit requiring a central venous catheter (CVC)
排除标准
- •Major blood coagulation disorders,
- •Any thrombotic formations within the vein,
- •Congenital or acquired deformity of neck or clavicle
- •Cannulation site infection, hematoma and surgery.
结局指标
主要结局
The overall access time
时间窗: During the venous cannulation procedure
Time from the ultrasound scanning to the ultrasound confirmation of the correct position of the guidewire into vein.
次要结局
- The guidewire time(During the venous cannulation procedure)
- The venous access time(During the venous cannulation procedure)
研究者
Trabelsi Becem
Associate Professor
University Tunis El Manar