The Diagnostic and Prognostic Value of Thrombin-Antithrombin Complex(TAT), α2-plasmin Inhibitor-plasmin Complex(PIC), Tissue Plasminogen Activator-inhibitor Complex(tPAI·C) and Thrombomodulin(TM) in Sepsis-induced Coagulopathy
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 入组人数
- 210
- 主要终点
- Thrombin-antithrombin complex(TAT), α2-plasmin inhibitor-plasmin complex(PIC), tissue plasminogen activator-inhibitor complex(tPAI·C) and thrombomodulin(TM) level
研究概览
简要总结
In order to evaluate the diagnostic and prognostic value of thrombin-antithrombin complex(TAT), α2-plasmin inhibitor-plasmin complex(PIC), tissue plasminogen activator-inhibitor complex(tPAI·C) and thrombomodulin(TM) in sepsis-induced coagulopathy(SIC), hospitalized patients with sepsis were prospectively included. Plasma TAT, PIC, tPAI·C,TM levels within 24 h after sepsis diagnosis were detected by MCL60 chemiluminescence analyzer. According to the SIC score (≥4), they were divided into SIC group and non-SIC group, and ROC curve analysis was performed according to the biomarker test results.
详细描述
Thrombin-antithrombin complex(TAT), α2-plasmin inhibitor-plasmin complex(PIC), tissue plasminogen activator-inhibitor complex(tPAI·C) and thrombomodulin(TM) can evaluate vascular endothelial damage, thrombin and plasminase activation, and have clinical significance in early diagnosis of DIC, thrombotic disease and monitoring of thrombolysis efficacy. However, whether these biomarkers can be used for early diagnosis of SIC is unclear.
In order to evaluate the diagnostic value of TAT, PIC, tPAI·C and TM in sepsis-induced coagulopathy(SIC), hospitalized patients with sepsis were prospectively included. Plasma TAT, PIC, tPAI·C,TM levels within 24 h after sepsis diagnosis were detected by MCL60 chemiluminescence analyzer. According to the SIC score (≥4), they were divided into SIC group and non-SIC group, and receiver operator characteristic(ROC) curve analysis was performed according to the biomarker test results. The area under the curve(AUC) was used to determine whether TAT, PIC, tPAI·C and TM could be used as biomarkers for SIC diagnosis. If AUC is between 0.7 and 0.9, this indicator has diagnostic value.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Septic patients who meet the diagnostic criteria of sepsis 3.0.
排除标准
- •age < 18 years old, heparin induced thrombocytopenia, thrombotic thrombocytopenic purpura, antiphospholipid syndrome or liver cirrhosis classified as Child-Pugh grade C and patients with a current treatment that interfered with coagulation (anticoagulants).
结局指标
主要结局
Thrombin-antithrombin complex(TAT), α2-plasmin inhibitor-plasmin complex(PIC), tissue plasminogen activator-inhibitor complex(tPAI·C) and thrombomodulin(TM) level
时间窗: 4 hours
Plasma TAT, PIC, tPAI·C,TM levels within 24 h after sepsis diagnosis were detected by MCL60 chemiluminescence analyzer. According to the SIC score (≥4), they were divided into SIC group and non-SIC group, and receiver operator characteristic (ROC)curve analysis was performed according to the biomarker test results. The area under the curve(AUC) was used to determine whether TAT, PIC, tPAI·C and TM could be used as biomarkers for SIC diagnosis. If AUC is between 0.7 and 0.9, this indicator has diagnostic value.
次要结局
未报告次要终点