临床试验/NCT05568134
NCT05568134已完成不适用

Correlations Between CGM and Serum Glucose During OGTT Testing for CFRD

Children's Hospital of Philadelphia1 个研究点 分布在 1 个国家目标入组 14 人开始时间: 2023年7月17日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
14
试验地点
1
主要终点
Agreement between plasma glucose, CGM measured glucose using the Dexcom G7, and GTT@home glucose

研究概览

简要总结

Although early detection and treatment of cystic fibrosis-related diabetes (CFRD) can lead to significant clinical improvements and prolong life, rates of screening are poor likely due to the burdensome nature of oral glucose tolerance testing (OGTT). The investigators propose to assess the feasibility and accuracy of two screening tools, continuous glucose monitoring (CGM) and a home OGTT kit (GTT@home). If this pilot study reveals acceptable accuracy of either device, this study will allow for future studies exploring home-based OGTT screening.

详细描述

The investigators hypothesize that there will be strong agreement between plasma glucose and glucose as measured by either CGM or GTT@home at three different timepoints during an OGTT: fasting, 1-hour, and 2-hours.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
10 Years 至 —(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Diagnosis of cystic fibrosis
  • ≥ 10 years of age
  • Fluency in written and spoken English as the GTT@Home is currently only available in English

排除标准

  • Hospitalization or treatment with IV antibiotics or supraphysiologic glucocorticoids within 4 weeks
  • Major medical or psychiatric disorders other than CF
  • Use of medications known to impact the accuracy of the Dexcom G7 (hydroxyurea, >2g acetaminophen per day)
  • History of severe adhesive reactions that may lead to an inability to tolerate CGM wear

结局指标

主要结局

Agreement between plasma glucose, CGM measured glucose using the Dexcom G7, and GTT@home glucose

时间窗: 2 hour mark in OGTT

Differences in the 2 hour glucose during the OGTT will be measured by the difference in mg/dl between plasma glucose, CGM measured glucose, and GTT@home measured glucose.

次要结局

  • Agreement between the categorical diagnosis of normal glucose tolerance (NGT), impaired glucose tolerance (IGT), indeterminate glycemia (INDET), and CFRD as defined by plasma glucose, CGM glucose, and GTT@home glucose.(Up to 2 hours)
  • Difference between plasma glucose and CGM measured glucose after the fasting glucose(Up to 20 minutes after the fasting glucose)
  • Difference between plasma glucose and CGM measured glucose after the 2 hour mark during the OGTT.(Up to 20 minutes after the 2 hour mark in the OGTT)
  • Impact of wearing a real-time CGM on participants' awareness of the importance of screening for and diagnosing CFRD.(Within 2 weeks after removal of the CGM)
  • The ability of untrained participants to successfully complete the GTT@home kit without any guidance from the research team(Up to 2 hours)
  • Difference between plasma glucose and CGM measured glucose after the 1 hour mark during the OGTT.(Up to 20 minutes after the 1 hour mark in the OGTT)
  • Perceived benefits and burdens of CGM use(Within 2 weeks after removal of the CGM)