Aerobic Versus Resistance Exercises on Liver Enzymes Following Burn Injuries
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 发起方
- 入组人数
- 60
- 试验地点
- 2
- 主要终点
- Measures of AST and ALT Liver enzymes post treatment
研究概览
简要总结
- Subjects:
Sixty patients suffering from partial thickness burn with burned body surface area (BBSA) about 30% to 50% will be randomly divided into two equal groups each one has 30 patients. 2. Equipment and tools:
2.1. Measurement equipment: Spectrophotometer device. 2.2. Therapeutic equipment and tools: Treadmill device for aerobic exercises and dumbbells and sand bags for resistance exercises.
详细描述
Sixty patients who have partial thickness burn with burned body surface area (BBSA) about 30% to 50% will participate in this study after their release from intensive care unit. Their ages will be ranged from 20 to 45 years. The participants will be selected from Orabi hospital and randomly distributed into two equal groups. In this study the patients will be randomly assigned into two equal groups (30 patients for each group):
1.1(a) Group A (Aerobic exercise group): This group includes 30 burned patients who will receive aerobic exercises 8 weeks (3times/week) in form of (treadmill device) in addition to their physical therapy program (splinting, stretching ex. and ROM ex.) and medical treatment.
1.1(b) Group B (Resistance exercise group): This group includes 30 burned patients who will receive resistance exercises 8 weeks (3times/week) by using dumbbells and sand bags in addition to their physical therapy program (splinting, stretching ex. and ROM ex.) and medical treatment.
3.1-Measurement procedures:
- Serum blood draws will be taken by certified technicians with the participant in a seated position.
- Spectrophotometry is the measurable analysis technique using the electromagnetic spectra. It deals with the ranges of wavelengths such as near ultraviolet, near infrared and visible light. A device called a spectrophotometer is used to measure the absorbance or transmittance through a liquid sample. The spectrophotometer takes a measurement at a specific wavelength and it is possible to choose any wavelength in the spectrophotometers register as the double beam sends a beam through a blank reference sample and one through the sample to be measured (Nilsson, 2010).
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Sequential
- 主要目的
- Treatment
- 盲法
- Single (Participant)
入排标准
- 年龄范围
- 20 Years 至 45 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •-The subject selection will be according to the following criteria:
- •Age range between 20-45 years.
- •Male and female patients will participate in the study.
- •All patients have burn with BBSA about 30% to 50%.
- •All patients enrolled to the study will have their informed consent.
排除标准
- •The potential participants will be excluded if they meet one of the following criteria:
- •Cardiac diseases.
- •Burn of sole of foot.
- •Exposed hand or foot tendons.
- •Lower limb amputation.
- •History of liver diseases.
- •Body mass index (BMI=kg/cm2)<30%.
结局指标
主要结局
Measures of AST and ALT Liver enzymes post treatment
时间窗: 2 months
Measures of AST and ALT Liver enzymes post 8 weeks of treatment for 10 patients of Aerobic group and 10 patients of resistance group.
次要结局
未报告次要终点
研究者
Aya Gamal Fawzy El-Sayed
Assistant lecturer
Cairo University
