Development of a Simple, Fast and Portable Recombinase Aided Amplification (RAA) Assay for 2019-nCoV

Beijing Ditan Hospital1 个研究点 分布在 1 个国家目标入组 50 人开始时间: 2020年1月1日最近更新:
适应症

试验速览

阶段
不适用
发起方
入组人数
50
试验地点
1
主要终点
Detection sensitivity is greater than 95%

研究概览

简要总结

In late December 2019, several local health facilities reported clusters of patients with pneumonia of unknown cause that were epidemiologically linked to a seafood and wet animal wholesale market in Wuhan, Hubei Province, China. It is now confirmed that the etiology of this outbreak is a novel coronavirus, namely, 2019-nCoV. Of critical importance is rapid and simple diagnostic method to be used in clinical settings to timely inform and refine strategies that can prevent, control, and stop the spread of 2019-nCoV. Recombinase aided amplification (RAA) assay is a novel isothermal nucleic acid amplification technique in recent years, which has a variety of the advantages including high specificity and sensitivity, rapid detection (30 min), low cost, low equipment requirements and simple operation. The has successfully detected a variety of pathogens using this technique. To develop a RAA assay for 2019-nCoV with the advantages of high speed, simple operation and low cost, and overcomes the shortcomings of the existing molecular detection methods. The investigators established a real time reverse-transcription RAA (RT-RAA) assay for detection of 2019-nCoV. This assay was performed at 42°C within 30min using a portable real-time fluorescence detector, Recombinant plasmids containing conserved ORF1ab genes was used to analyze the specificity and sensitivity. Clinical specimens from patients who were suspected of being infected with 2019-nCoV were used to evaluate the performance of the assay. In parallel, The investigators also used the commercial RT-qPCR assay kit for 2019-nCoV as a reference.

详细描述

In late December 2019, several local health facilities reported clusters of patients with pneumonia of unknown cause that were epidemiologically linked to a seafood and wet animal wholesale market in Wuhan, Hubei Province, China. It is now confirmed that the etiology of this outbreak is a novel coronavirus, namely, 2019-nCoV. Of critical importance is rapid and simple diagnostic method to be used in clinical settings to timely inform and refine strategies that can prevent, control, and stop the spread of 2019-nCoV. Recombinase aided amplification (RAA) assay is a novel isothermal nucleic acid amplification technique in recent years, which has a variety of the advantages including high specificity and sensitivity, rapid detection (30 min), low cost, low equipment requirements and simple operation. The investigators has successfully detected a variety of pathogens using this technique. To develop a RAA assay for 2019-nCoV with the advantages of high speed, simple operation and low cost, and overcomes the shortcomings of the existing molecular detection methods. The investigators established a real time reverse-transcription RAA (RT-RAA) assay for detection of 2019-nCoV. This assay was performed at 42°C within 30min using a portable real-time fluorescence detector, Recombinant plasmids containing conserved ORF1ab genes was used to analyze the specificity and sensitivity. Clinical specimens from patients who were suspected of being infected with 2019-nCoV were used to evaluate the performance of the assay. In parallel, The investigators also used the commercial RT-qPCR assay kit for 2019-nCoV as a reference. Patients who were suspected of being infected with 2019-nCoV in the hospital.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
1 Year 至 90 Years(Child, Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Suspected cases (formerly observed cases)
  • Meet the following 2 at the same time:
  • Epidemiological history There was a history of travel or residence in Wuhan within two weeks before the onset of illness; or patients who had had fever from Wuhan with respiratory symptoms within 14 days before the onset of illness, or had clustered onset.
  • Clinical manifestations
  • It has the imaging characteristics of pneumonia mentioned above;
  • The total number of white blood cells is normal or decreased, or the lymphocyte count is decreased in the early stage of onset.
  • confirmed cases On the basis of meeting the criteria for suspected cases, sputum, throat swabs, lower respiratory tract secretions, and other specimens were tested by real-time fluorescent RT-PCR for positive nucleic acid detection of new coronavirus; or viral gene sequencing was highly homologous with known new coronaviruses.

排除标准

  • Influenza virus, parainfluenza virus, adenovirus, respiratory syncytial virus, rhinovirus, human metapneumovirus, SARS coronavirus, and other known other viral pneumonia;
  • Mycoplasma pneumoniae, chlamydia pneumonia, and bacterial pneumonia; non-infectious diseases such as vasculitis, dermatomyositis, and organizing pneumonia.

结局指标

主要结局

Detection sensitivity is greater than 95%

时间窗: at baseline

Detection sensitivity is greater than 95%

Detection specificity is greater than 95%

时间窗: at baseline

Detection specificity is greater than 95%

次要结局

  • Consistent with existing universal reagent detection rates greater than 95%(at baseline)

研究者

发起方
Beijing Ditan Hospital
申办方类型
Other
责任方
Principal Investigator
主要研究者

Yao Xie

Director of the Second Division of Liver Diseases