Comparison of the Quality of Vision Provided by AMO Tecnis Z9000 Three-piece Silicone Posterior Chamber Intraocular Lens and Alcon Laboratories MA60 Acrysof Three-piece Acrylic Posterior Chamber Intraocular Lens

Singapore National Eye Centre2 个研究点 分布在 1 个国家目标入组 80 人开始时间: 2005年7月1日最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
入组人数
80
试验地点
2
主要终点
The primary outcome of this comparative study is the best corrected mesopic log contrast sensitivity function of eyes implanted with Z9000 and MA60 lenses at 6 cycles/degree, 90-120 days postoperatively.

研究概览

简要总结

This study is a comparison of the quality of vision provided by AMO Tecnis Z9000 three-piece silicone posterior chamber intraocular lens and Alcon Laboratories MA60 three-piece acrylic posterior chamber intraocular lens.

详细描述

Today, intraocular lenses (IOLs) are routinely implanted after cataract extraction. Cataract surgical techniques are constantly developing due to innovations in surgical implantation and IOL manufacturing processes. Although material development and surgical implantation have advanced extensively during the past several years, there has been little attention paid to the improvement of the optical quality of IOLs.

It has been documented that the vision of an IOL patient is no better than that of a person with healthy eyes of a similar age, i.e., when a 65-year-old patient with cataracts has them removed and implanted with an IOL, the resulting visual outcome is no better than the visual quality of a 65-year-old without cataracts. The fact that the visual quality of the IOL patients is no better than that of their same-age counterparts is surprising because an IOL is optically superior to the natural crystalline lens. This fact may be explained by aberrations.

Aberrations cause incoming light that would otherwise be focused to a point to be blurred, which in turn causes a reduction in visual quality. This reduction in quality is more severe under low luminance conditions because ocular aberrations increase when the pupil size gets larger. The Z9000 is an IOL that is designed to counteract the spherical aberration of the cornea and thus improve the resulting visual quality of IOL patients.

Different materials and lens designs result in different visual quality. The handling of the lens, proper centration in the eye, the postoperative course, and the optical image may vary depending on the design of the lens. Two lenses will be compared: AMO Tecnis Z9000 three-piece silicone lens and Alcon Laboratories MA60 three-piece acrylic lens.

This will be a randomized, evaluator-masked study in bilateral cataract surgery patients. Each patient will be assigned to a AMO Tecnis Z9000 lens in one eye and an Alcon Laboratories MA60 lens in the other eye. All first surgeries will be on the right eye. A randomization list will be used to decide lens allocation.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single

入排标准

年龄范围
50 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Bilateral cataracts, eligible for phacoemulsification with primary implantation of a posterior chamber IOL
  • Males and females 50 to 80 years of age
  • Expected maximum of 6-weeks and minimum of 3 weeks interval between a single patient's surgeries
  • Best corrected visual acuity (BCVA) should be no better than 20/40 in the presence of a glare source. (In the early treatment diabetic retinopathy study [ETDRS] visual acuity chart, better than 20/40 will be at least 3 letters read correctly in the 20/30 line).
  • Best corrected visual acuity projected by Potential Acuity Meter (PAM) or other reliable potential acuity test procedure to be 20/30 or better in each eye after cataract removal and IOL implantation.
  • Naturally dilated pupil size (in dim light) ≥ 4.0 mm (with no dilation medications) - both eyes
  • Anticipated correction with an IOL of +6 to +30 diopters (both eyes)
  • Evidence of a personally signed and dated informed consent document indicating the patient (or a legally acceptable representative) has been informed of all pertinent aspects of the trial
  • Willing and able to comply with scheduled visits and other study procedures

排除标准

  • Preoperative pathology: amblyopia, rubella cataract, proliferative diabetic retinopathy, shallow anterior chamber, macular edema, retinal detachment, aniridia or iris atrophy, uveitis, history of iritis, iris neovascularization, medically uncontrolled glaucoma, microphthalmus or macrophthalmus, optic nerve atrophy
  • Previous intraocular or corneal surgery, including refractive surgery, corneal transplant
  • Other pathologies potentially affecting visual acuity, e.g., macular degeneration, glaucoma with the presence of visual field defects
  • An increased risk for complications which could require vitreoretinal surgery
  • Corneal irregularities potentially affecting visual acuity, e.g., keratoconus, corneal dystrophy
  • Corneal opacities
  • Keratometric astigmatism exceeding 1.5 diopters
  • Patient in whom postoperative refractive error is planned to be different between fellow eyes (anisometropia) such as in cases where postoperative refraction is planned for mono-vision
  • Current contact lens usage (within 6 months prior to first surgery and/or during the study)
  • Other ocular surgery at time of cataract extraction
  • Uncontrolled diabetes
  • Any neurological condition that might interfere with performance of required tests
  • Immune deficiency disease
  • Other severe acute or chronic medical or psychiatric condition or laboratory abnormality that may increase the risk associated with study participation or study device implantation or may interfere with the interpretation of study results and, in the judgment of the investigator, would make the patient inappropriate for entry into this study
  • Use of any systemic or topical drug known to interfere with visual performance

结局指标

主要结局

The primary outcome of this comparative study is the best corrected mesopic log contrast sensitivity function of eyes implanted with Z9000 and MA60 lenses at 6 cycles/degree, 90-120 days postoperatively.

次要结局

  • The change in best corrected mesopic log contrast sensitivity function after cataract surgery (postoperatively minus preoperatively) at 1.5, 3, 6, 12, and 18 cycles/degree
  • Postoperative ocular complications/adverse events
  • Logarithm of the minimum angle of resolution (LogMAR) visual acuity
  • The best corrected mesopic log contrast sensitivity function of eyes implanted with Z9000 and MA60 lenses at 1.5, 3, 12, and 18 cycles/degree, 90-120 days postoperatively
  • The residual spherical aberrations of the postoperative eye using wavefront analysis