Clinical Evaluation Of SonR Atrial Lead In Paradym RF Device SORIN GROUP'S New ICD Plateform
试验速览
- 阶段
- 3 期
- 状态
- 已完成
- 发起方
- LivaNova
- 入组人数
- 100
- 试验地点
- 2
- 主要终点
- Evaluation of the SonR lead safety
研究概览
简要总结
Sorin Group has developed a new atrial lead which is under evaluation during this study. The SonR atrial lead presents a new sensor in the tip of the lead and allows a new feature; interventricular (VV) and atrioventricular (AV) delay (VVD and AVD) optimization.
The new RV autothreshold algorithm has been implemented in the CRT-ICD and will help the physician in his diagnosis avoiding potential lost of capture.
The ICD device has also the capability to be remotely interrogated through the remote monitoring system whose performances will be reported during the study.
Finally, the study will report the electrical and handling performances of the new left ventricular lead.
详细描述
In this study, the sponsor aims at:
- Demonstrating the safety of the atrial SonR lead;
- Demonstrating the performances of the right ventricular autothreshold algorithm ;
- Reporting the adverse events documented in the study;
- Reporting electrical performances of Sorin Group PARADYM ICD, in order to validate that the performances of those devices are in conformance with longevity and effectiveness objectives;
- Reporting the Sorin atrial SonR and Situs 2 MV left ventricular leads performances;
- Reporting the SonR atrial lead mechanical handling.
- Reporting all information from SonR sensor to validate the SonR data exploitation and the AVD/VVD optimization.
- Reporting the Situs 2 MV LV lead mechanical handling.
- Assessing the user satisfaction (patient and physician) of the remote monitoring solution and the overall availability of the system in terms of data.
Thus, this study intends to show that PARADYM RF ICD operate safely and appropriately in intended-use as part of an ICD system.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Single Group
- 主要目的
- Diagnostic
- 盲法
- None
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Patient eligible for implantation of a CRT 9770 device accordingly to the relevant currently-approved ACC/AHA/ESC guidelines or any relevant currently approved local guidelines for the implantation or replacement of triple-chamber ICD
- •Implanted with atrial SonR lead
- •Signed and dated informed consent
排除标准
- •VT/VF is associated with drug toxicity, electrolyte imbalance, hypoxia, or other reversible cause;
- •VT/VF occurred during the acute phase of infarction (< 3 weeks) or during an unstable ischemic phase;
- •VF was caused by electrocution;
- •Incessant VT/VF;
- •Patient is unable to attend the scheduled follow-ups at the implanting centre;
- •Patient is already enrolled in another ongoing clinical study;
- •Patient is unable to understand the aim of the study and its procedure;
- •Patient refuses to cooperate;
- •Patient is unable or refuses to provide informed consent;
- •Patient is minor (less than 18-year old);
- •Patient is pregnant;
- •Patient has life expectancy of less than 1 year;
- •Patient is forfeiture of freedom or under guardianship.
结局指标
主要结局
Evaluation of the SonR lead safety
时间窗: 3 months
Complication free rate of the SonR lead superior to 90 %
次要结局
- Incidence of adverse events(12 months)
- ICD electrical performances(12 months)
- Evaluation of the AV/VV delays optimization(3 months)
- Evaluation of the left ventricular lead performances(12 months)
- Evaluation of the Remote Monitoring Solution(12 months)
- Evaluation of the right ventricular autothreshold performances(1 month)
- Evaluation of the SonR atrial lead performance(3 months)