跳至主要内容
临床试验/NCT07697144
NCT07697144尚未招募不适用

Effect of Adding Vasopressin on Cardiac Output, Blood Pressure, Diuresis, and Tissue Perfusion Indices in Patients With Septic Shock

Assistance Publique - Hôpitaux de Paris8 个研究点 分布在 1 个国家目标入组 200 人开始时间: 2026年8月1日最近更新:
适应症

试验速览

阶段
不适用
状态
尚未招募
入组人数
200
试验地点
8
主要终点
To describe and compare the evolution of cardiac index between inclusion and 20 minutes after vasopressin initiation in patients with septic shock, according to hemodynamic profiles identified a posteriori from variables collected at the time of vasopre

研究概览

简要总结

In patients with septic shock, vasopressin is increasingly used in combination with norepinephrine, but its timing of initiation remains heterogeneous and its clinical hemodynamic effects are still insufficiently characterized. Available data suggest variable responses, which may depend on the hemodynamic phenotype at the time of treatment initiation. In particular, the effects of vasopressin may differ according to the presence of preload dependency, baseline cardiac output, impaired systolic function, or baseline diastolic arterial pressure, reflecting the degree of vasoplegia. In this context, the VASO-PHENO study aims to provide a detailed and dynamic description of the early hemodynamic and clinical effects of vasopressin initiation in septic shock.

To date, no clinical study has systematically and dynamically evaluated the effects of vasopressin on central and peripheral hemodynamic parameters according to the hemodynamic profile at the time of its initiation. Describing these effects appears essential to better understand the variability in clinical responses and to contribute to a more rational and personalized approach to vasopressor escalation in septic shock.

详细描述

In patients with septic shock, hemodynamic profiles are highly heterogeneous. From a pathophysiological perspective, three main hemodynamic phenotypic components may contribute to the septic shock state:

  • preload dependency;
  • impaired myocardial function, leading to a cardiac output that is inadequate to meet oxygen demand;
  • vasoplegia.

In some of these contexts, the introduction of vasopressin, as a pure vasoconstrictor, may be inappropriate or even harmful, by impairing cardiac output or exposing the patient to excessive vasoconstriction and a subsequent risk of ischemia.

Thus:

  • In the presence of impaired myocardial function, defined by reduced cardiac output and/or impaired left ventricular ejection fraction, vasopressin initiation may lead to a decrease in cardiac output;
  • In the presence of vasoplegia, the effects of vasopressin on mean arterial pressure and microcirculatory indices, such as capillary refill time, mottling, and urine output, may vary according to the severity of the initial vasoplegia, notably reflected by diastolic arterial pressure;
  • In the presence of persistent preload dependency, the initiation of a pure vasoconstrictor may either increase cardiac output by increasing venous return, or worsen microcirculatory alterations by enhancing vasoconstriction in a context of hypovolemia.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Age ≥ 18 years;
  • Hospitalized in an intensive care unit;
  • Presenting with septic shock according to Sepsis-3 criteria;
  • For whom the treating clinician wishes to initiate vasopressin as second-line therapy as part of routine care;
  • Undergoing hemodynamic monitoring with a PiCCO2 device (Pulsion Medical Systems, Getinge, Feldkirchen, Germany) or pulmonary artery catheterization as part of routine care.

排除标准

  • Patient already receiving vasopressin;
  • Pregnancy;
  • Patient under legal protection;
  • Patient unwilling to participate in the study.

结局指标

主要结局

To describe and compare the evolution of cardiac index between inclusion and 20 minutes after vasopressin initiation in patients with septic shock, according to hemodynamic profiles identified a posteriori from variables collected at the time of vasopre

时间窗: T0 = inclusion. T20 = 20 minutes after the introduction of the vasopressin

Hemodynamic profiles will not be defined a priori. They will be identified a posteriori using a supervised clustering analysis based on variables measured at inclusion and selected for their pathophysiological relevance: * presence of preload dependency at the time of vasopressin initiation (yes/no); * cardiac index at inclusion; * diastolic arterial pressure at inclusion; * left ventricular ejection fraction (LVEF).

次要结局

  • To describe the evolution of cardiac index between inclusion (T0), T1h, T3h, and T24h after vasopressin initiation(T0 = inclusion, T1h = 1 hour after the introduction of the vasopressin, T3h = 3 hours after the introduction of the vasopressin. T24h = 24 hours after the introduction of the vasopressin)
  • Change in mean arterial pressure after vasopressin initiation(T0 = inclusion, T20 = 20 minutes after the introduciton of the vasopressin, T1h = 1 hour after the introduction of the vasopressin, T3h = 3 hours after the introduction of the vasopressin. T24h = 24 hours after the introduction of the vasopressin)
  • In patients monitored with a Swan-Ganz® pulmonary artery catheter: to describe the evolution of pulmonary artery occlusion pressure between inclusion (T0), T20, T1h, T3h, and T24h after vasopressin initiation3.(T0 = inclusion, T20 = 20 minutes after the introduciton of the vasopressin, T1h = 1 hour after the introduction of the vasopressin, T3h = 3 hours after the introduction of the vasopressin. T24h = 24 hours after the introduction of the vasopressin)
  • In patients monitored with a transpulmonary thermodilution device combined with pulse contour analysis (PiCCO®): to describe the evolution of indexed extravascular lung water between inclusion (T0), T20, T1h, T3h, and T24h after vasopressin initiation(T0 = inclusion, T20 = 20 minutes after the introduciton of the vasopressin, T1h = 1 hour after the introduction of the vasopressin, T3h = 3 hours after the introduction of the vasopressin. T24h = 24 hours after the introduction of the vasopressin)
  • To describe the evolution of mean arterial pressure between inclusion (T0), T20, T1h, T3h, and T24h after vasopressin initiation, according to diastolic arterial pressure at inclusion.(T0 = inclusion, T20 = 20 minutes after the introduciton of the vasopressin, T1h = 1 hour after the introduction of the vasopressin, T3h = 3 hours after the introduction of the vasopressin. T24h = 24 hours after the introduction of the vasopressin)
  • Change in urine output during the first 24 hours after vasopressin initiation(Urine output will be assessed every 2 hours from the introduction of vasopressine (T0) to 24 hours after the introduction of the vasopressine (T24))
  • Change in capillary refill time after vasopressin initiation(T0 = inclusion, T20 = 20 minutes after the introduciton of the vasopressin, T1h = 1 hour after the introduction of the vasopressin, T3h = 3 hours after the introduction of the vasopressin. T24h = 24 hours after the introduction of the vasopressin)
  • To describe the evolution of the mottling between the introduction of vasopressin (T0), T20, T1h, T3h, and T24h after vasopressin initiation, according to the evolution of the mean arterial pressure, diastolic arterial pressure, and of the cardiac output(T0 = inclusion, T20 = 20 minutes after the introduciton of the vasopressin, T1h = 1 hour after the introduction of the vasopressin, T3h = 3 hours after the introduction of the vasopressin. T24h = 24 hours after the introduction of the vasopressin)
  • To describe the evolution of arterial lactate between the introduction of vasopressin (T0), T20, T1h, T3h and T24h after vasopressin initiation, according to the evolution of the mean arterial pressure, diastolic arterial pressure and cardiac output(T0 = inclusion, T20 = 20 minutes after the introduction of the vasopressin, T1h = 1 hour after the introduction of the vasopressin, T3h = 3 hours after the introduction of the vasopressin. T24h = 24 hours after the introduction of the vasopressin)
  • To describe the evolution of the cardiac output between the introduction of vasopressin (T0), T20, T1H, T3h and T24h after vasopressin initiation, according to the initial left ventricular ejection fraction.(T0 = inclusion, T20 = 20 minutes after the introduction of the vasopressin, T1h = 1 hour after the introduction of the vasopressin, T3h = 3 hours after the introduction of the vasopressin. T24h = 24 hours after the introduction of the vasopressin)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (8)

Loading locations...

相似试验