跳至主要内容
临床试验/NCT06771700
NCT06771700招募中不适用

Feasibility of an Intra-operative and Non-fluoroscopic Subcutaneous ICD Positioning and Assessment of the PRAETORIAN Score During Implantation: a Pilot Study

Universitätsklinikum Köln3 个研究点 分布在 1 个国家目标入组 20 人开始时间: 2025年3月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
招募中
入组人数
20
试验地点
3
主要终点
PRAETORIAN

研究概览

简要总结

This trial investigates two key aspects of the S-ICD implantation process. 1) For S-ICD implantation a pre-operative x-ray-based assessment of the anatomy and location of the heart is required. This study seeks to investigate the feasibility of US to potentially replace the need for x-ray 2) The PRAETORIAN score predicts defibrillation test success in subcutaneous ICD implantation but can only be calculated after the procedure. This pilot study aims to evaluate the feasibility of US determining the PRAETORIAN score intraoperatively. Lead-to-sternum distance and generator position measurments during the implantation procedure will be evaluated. Twenty consecutive patients scheduled for S-ICD implantation will be enrolled. The study involves no deviation from standard implantation procedures and requires no follow-up beyond standard post-operative chest X-ray on day one.

详细描述

This trial investigates two key aspects of S-ICD implantation. 1) To achieve successful shock conversion of an arrhythmia with the S-ICD, the optimal position of the electrode and the device are paramount. A pre-operative x-ray-based assessment of the anatomy and location of the heart is required. Using a dummy electrode and device placed on the patient's chest, the desired position is determined through fluoroscopy, and it is marked on the patient's skin. In this trial US will be used to determine the ideal lead and device position. As the current standard, the X-ray method will then confirm ideal positioning before the device is implanted.

  1. The PRAETORIAN score is an established tool to predict defibrillation test success in subcutaneous ICD implantation but can only be calculated post-procedure using chest X-ray. This pilot study aims to evaluate the feasibility of determining the PRAETORIAN score intra-operatively. This pilot study will assess whether lead-to-sternum distance and generator position can be accurately measured during the implantation procedure by manual measurements with non-fluoroscopic means. This would potentially allow risk stratification before intra-operative defibrillation testing. Ten consecutive patients scheduled for S-ICD implantation will be enrolled. The study involves no deviation from standard implantation procedures and requires no follow-up beyond standard post-operative chest X-ray on day one. If successful, this approach could improve implantation safety by identifying high-risk patients before defibrillation testing.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Other
盲法
None

入排标准

性别
All
接受健康志愿者
否

入选标准

  • •consecutive patients presenting for S-ICD implantation at our institution

排除标准

  • •patients unable to consent.
  • •pregnancy

研究组 & 干预措施

S-ICD Implantation

Experimental

Patients are implanted with an S-ICD according to standard clinical practice. 1) The ideal lead and device position are determined using the new US method. Any deviation by more than 0.5 cm is counted as a significant deviation. 2) The intraoperative PRAETORIAN Score is calculated based on additional intraoperative measurements.

干预措施: Intraoperative PRAETORIAN Score (Diagnostic Test)

结局指标

主要结局

PRAETORIAN

时间窗: 1 day after the device implantation, when chest x-ray is available

The intraoperative PRAETORIAN Score is correlated with the regular PRAETORIAN Score

次要结局

未报告次要终点

研究者

申办方类型
Other
责任方
Sponsor

研究点 (3)

Loading locations...

相似试验