Clinical Evaluation of Safety and Effectiveness of the BackBeat Medical Moderato System in Patients With Hypertension: A Double-Blind Randomized Trial - PV Loops Sub-study

BackBeat Medical Inc1 个研究点 分布在 1 个国家目标入组 5 人开始时间: 2016年9月15日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
5
试验地点
1
主要终点
Change in the LV pressures (mmHg)

研究概览

简要总结

The position of the RV lead may have an important role in the effectiveness of the Programmable Hypertension Control (PHC) therapy by the Moderato pacemaker eliciting a lag from which RV signals (QRS) are identified.

The study attempts to measure RV Pressure and RV Volume with PHC in two RV lead locations.

详细描述

Subjects found eligible for participation in the CS-03 study, who are indicated for a de novo pulse generator implant at the center participating in this sub-study and who are not 100% dependent on RV pacing are eligible for participation in this sub-study.

Patients receiving a pacemaker pulse generator exchange or who are 100% pacemaker dependent may not participate.

Eligible patients will be provided with an Informed Consent specific to this sub-study and if patients choose to participate, patients will be asked to sign the Informed Consent and will then undergo the procedures described below.

Patients will be prepared and draped for the Moderato implant procedure as detailed in the main CS-03 study protocol.

Subjects will be instrumented prior to the Moderato Pacemaker implant procedure.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Subject was included in the CS-03 study
  • •Subject indicated for a de novo pulse generator implant

排除标准

  • •Subject was excluded from the CS-03 study
  • •Subject is not 100% dependent on RV pacing
  • •Subject receiving a pacemaker pulse generator exchange
  • •Subject is unwilling or cannot provide Informed Consent for this sub study

研究组 & 干预措施

RV location

Experimental

All included subjects will undergo the PV loop test with 'BackBeat PHC' ON and OFF

干预措施: BackBeat-PHC (Device)

结局指标

主要结局

Change in the LV pressures (mmHg)

时间窗: up to 2 hr

LV pressure will be assessed in two RV electrode lead locations with BackBeat PHC ON and OFF

Change in the LV volumes (ml)

时间窗: up to 2 hr

LV volume will be assessed in two RV electrode lead locations with BackBeat PHC ON and OFF

次要结局

  • Change in the pressure-volume ratio(up to 2 hr)

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验

CS-03 Pressure-Volume Loop Sub-study With RV Lead... | 临床试验