Predictive Value of Diaphragm Function Monitoring for Weaning in Mechanically Ventilated Patients: a Prospective Observational Cohort Study

Peking Union Medical College Hospital1 个研究点 分布在 1 个国家目标入组 25 人开始时间: 2022年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
入组人数
25
试验地点
1
主要终点
EADI ( diaphragm electrical activity)

研究概览

简要总结

The reason of failure of weaning from mechanical ventilation is that their respiratory loads exceeding the capacity of their respiratory muscles. The electric activity of diaphragm (EADI) allows quantification of the neural respiratory drive to the diaphragm. The aim of this study is to evaluate diaphragmatic ultrasound related parameters and electric activity of diaphragm (EADI) during SBT and postural changes to predict weaning outcome.

详细描述

The reason of failure of weaning from mechanical ventilation is that their respiratory loads exceeding the capacity of their respiratory muscles. The aim of this study is to evaluate diaphragmatic ultrasound related parameters and electric activity of diaphragm (EADI) during SBT and postural changes to predict weaning outcome. EADI catheter consists of a nasogastric feeding tube equipped with a multiple-array esophageal electrode that provides real time access to EADI.

Patients intubated and ventilated for at least 48 h were eligible for inclusion in the study.

After the ward physician judged that the patients' condition met the offline standard, patients were prepared to conduct spontaneous breathing trial (SBT). All recruited patients were placed EADI catheter.

The protocol started with patients ventilated on a PSV of 10 cm H2O above a positive end-expiratory pressure (PEEP) of 4-5 cm H2O. Then record ventilator parameters, EADI parameters (including maximum EADI, minimum EADI, area under the curve of the EADI during inspiratory time) and diaphragmatic ultrasound related parameters (diaphragm thickness and diaphragm displacement) respectively in the semi-seated and supine positions. Then assist was removed and a 30-minute SBT was performed with continuous positive airway pressure (CPAP) of 4-5 cm H2O at the previous level of FiO2. At 0, 1, 5, 10, 20 and 30 minutes into the SBT vital signs, ventilatory parameters (including RR, Vt, Ppeak, PEEP, P0.1, MV) were collected. Arterial blood gases were sampled at the start and the end of the SBT.

The SBT was considered to be a failure if at least one the following criteria was present: (1) blood oxygen saturation (SpO2) of <90 % with a fraction of inspired oxygen (FiO2) of≥50 %; (2) acute respiratory distress (RR≥40/min, agitation, cyanosis); (3) systolic arterial blood pressure of ≥180 mmHg; (4) cardiac arrhythmias; (5) respiratory acidosis [pH<7.32 with an arterial carbon dioxide tension (PaCO2) of ≥50 mmHg]. If none of these failure criteria was present, the SBT was considered as successfully completed.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 18 years old Patients with acute respiratory failure and endotracheal intubation Invasive ventilator time ≥48 hours Switched to auxiliary ventilation mode and have weaning plan.

排除标准

  • Patients with severe neuromuscular diseases Patients treated with muscle relaxants Patients who have been or are about to be discontinued from life support Patients with esophageal and fundus varicose veins, digestive tract perforation or gastric tube insertion after upper digestive tract surgery contraindicated Pregnant patients.

结局指标

主要结局

EADI ( diaphragm electrical activity)

时间窗: 30 minutes since SBT was conducted

Utilizing NAVA catheter, the EADI allows quantification of the neural respiratory drive to the diaphragm.

次要结局

  • Diaphragm Neurodisplacement Efficiency(30 minutes since SBT was conducted)
  • Neuroventilatory Efficiency(30 minutes since SBT was conducted)