Reducing Oxygen Consumption in Critical Care
- Conditions
- Mechanical Ventilation Complication
- Registration Number
- NCT05796817
- Lead Sponsor
- Royal Brompton & Harefield NHS Foundation Trust
- Brief Summary
In normal practice oxygen supply can be easily met with existing hospital infrastructure. COVID - 19 however results in lung damage which greatly increases the amount of oxygen patients require - as a consequence some hospitals in the UK and other countries had situations where there was not enough oxygen for their inpatients.
COVID - 19 has caused many more patients to requiring assistance with their breathing using a ventilator. Due to the limited supply of sophisticated ventilators that 're-use' oxygen patients breathe out, some hospitals have used ventilators normally used by patients at home (domiciliary ventilators). Whilst these are inexpensive and commonly available, any oxygen the patient breathes out is simply released into the atmosphere.
The address this problem, and in turn reduce the oxygen demand on hospital infrastructure the biomedical engineering team (BME) at the Royal Brompton Hospital, London devised a simple 3-D printed modification which captures and reuses oxygen on commonly used domiciliary ventilators. Laboratory testing found this modification can increase the oxygen given by the ventilator without increasing the oxygen consumption of the ventilator - effectively reducing oxygen demand on hospital infrastructure.
This study will evaluate this modification in patients admitted to intensive care requiring assistance with their breathing. This will involve measuring oxygen levels on domiciliary ventilators (Breas Nippy 4+, ResMed Lumis 150 or Vivo 1, 2 or 3) with and without the modification and with small increases in oxygen supplied to the patient for a total study period of 2 hours.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 12
- Patient in critical care using a ResMed LumisTM 150, Breas® Nippy 4+ or Vivo 1, 2 or 3 ventilator or deemed safe by treating consultant safe to switch to one.
- 28% or more of entrained oxygen (FiO2)
- Judged to be safe to tolerate increased fraction of inspired oxygen for periods of 10 minutes
- Arterial line insitu for clinical reasons
- Thought to be clinically unstable during study protocol (2 hours)
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Arterial blood gas analysis - baseline After 10 minutes PaO2 with and without modification fitted
- Secondary Outcome Measures
Name Time Method Arterial blood gas - CO2 After 10 minutes of each experimental condition Arterial CO2 levels at each experimental condition
Arterial blood gas - modification and oxygen change After 10 minutes of each experimental condition Oxygenation with and without modification in place with 1, 2 and 3 litres added to baseline FiO2
Trial Locations
- Locations (1)
The Royal Brompton and Harefield Hospitals
🇬🇧London, United Kingdom