MedPath

Remote ECG Monitoring of TAVI Patients

Not Applicable
Conditions
Cardiac Valve Disease
Aortic Valve Stenosis
Interventions
Device: mobile Cardiac Arrhythmia Diagnostics Service (m-CARDS)
Registration Number
NCT03810820
Lead Sponsor
Population Health Research Institute
Brief Summary

After surgery, patients who undergo transcatheter aortic valve implantation (TAVI) are at risk of developing cardiac arrhythmias such as heart blocks and atrial fibrillation. Current practice is to monitor TAVI patients in hospital for 2-8 days post procedure using scarce and expensive hospital telemetry beds. This study will use a new monitoring service called mobile Cardiac Arrhythmia Diagnostics Service (m-CARDS) to risk stratify patient pre-TAVI and provide an added layer of monitoring that would support earlier discharge of suitably identified patients 24-hours post TAVI. The study will assess whether this strategy will significantly reduce the pressure on hospital resources while improving patient outcomes and experience.

Detailed Description

Aortic stenosis (AS), the most common valvular heart disease, occurs when there is a narrowing of the aortic valve opening. New transcatheter aortic valve implantation (TAVI, also called transcatheter aortic valve replacement \[TAVR\]), is a minimally invasive surgical procedure that is rapidly expanding as the dominant treatment modality for elderly patients with AS. Approximately 1000 patients will undergo TAVR surgery in Ontario in fiscal year 2018-2019 and that number is expected to increase to \~80% of all valve replacement surgery within the next 5 years.

Patients that undergo TAVI are at risk of developing cardiac arrhythmias such as heart block and atrial fibrillation and many are routinely monitored in-hospital for 5-8 days post-surgery. Currently, this monitoring is done using scarce and expensive hospital telemetry beds.

This study uses a novel clinical pathway including remote monitoring pre- and post-TAVI using a new service called mobile Cardiac Arrhythmia Diagnostics Service (m-CARDS™). m-CARDS™ consists of a patient cardiac monitoring device that transmits cardiac data in real time to a centralized center. Patients wearing the device can remain in the comfort of their own home while being monitored remotely. The monitoring device is Health Canada approved and has been used extensively. Because it is highly sensitive to cardiac arrhythmias, including all levels of heart block, it is ideally suited for this type of monitoring.

If this pathway is adopted across all centres it will significantly reduce the pressure on hospital resources while at the same time improve the patient experience, enabling them to get home sooner. Hospital telemetry is very expensive. Reducing the length of stay from 2-8 days on average to 24hr for many patients would represent cost savings to the hospitals and province.

While some studies show that patients could be discharged earlier, there is still significant variability in adopting a short length of stay post-TAVI due to a perceived need for inpatient monitoring and lack of adequate knowledge and data on feasibility of remote outpatient monitoring.

In addition, the pre-TAVR monitoring will enhance our ability to predict and plan for interventions such as permanent pacemaker implantation. The primary objective of this project will be to facilitate the implementation of this monitoring technology into a busy tertiary care setting and better understand the conditions necessary for successful implementation. This will be achieved through ongoing stakeholder engagement (patient, provider, and hospital administrators) at all stages of the implementation program and close evaluation of quality metrics to ensure fidelity of the m-CARDS™ system.

Overall, implementation of this system is expected to impact the following levels of the health care system:

i) Patient-Level: Improved quality of life through "better care closer to home" facilitated by physician supported monitoring before TAVI and post-TAVI discharge from hospital.

ii) Provider-Level/Organizational-Level: Integrate the m-CARDS™ system into a busy TAVI clinical care pathway that can be adapted at other TAVI centres and ensure physician/administrator engagement/confidence in this novel technology.

iii) System-Level: Reduced (1) hospital length of stay and associated costs, (2) readmissions and unplanned medical visits, and (3) likelihood of hospital acquired infections.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
240
Inclusion Criteria
  • All patients selected for TAVI procedure that do not meet exclusion criteria and provide informed consent.
Exclusion Criteria
  • Patients with prior PPM or ICD
  • Patient in-hospital awaiting TAVI
  • Resting 12-lead ECG shows first degree AV block, plus LAHB plus RBBB; high grade 2nd or 3rd degree heart block

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Outpatient TAVImobile Cardiac Arrhythmia Diagnostics Service (m-CARDS)Consecutive patients scheduled for outpatient TAVI.
Primary Outcome Measures
NameTimeMethod
Feasibility: Recruitment rateEnd of study (Approximately Month 24)

To achieve recruitment of at least 80% of eligible patients and to describe reasons for non-participation.

Feasibility: Participant adherence to monitoring pre-TAVIEnd of pre-TAVI monitoring period (Day 14)

To achieve patient level adherence to monitoring at least 80% of the expected time (total # of days (hours) of loop monitoring pre-TAVI).

Feasibility: Participant adherence to monitoring post-TAVIEnd of post-TAVI monitoring period (approximately Month 2 dependent on scheduling of TAVI procedure)

To achieve patient level adherence to monitoring at least 80% of the expected time (total # of days (hours) of loop monitoring post-TAVI).

Feasibility: Requirement for PPM pre-TAVIEnd of pre-TAVI monitoring period (Day 14)

Pre-TAVI identification of at least 5-10% of the cohort population who would need permanent pacemaker (either heart block or characteristics high risk for heart block).

Feasibility: Participant adherence to post-TAVI monitoring protocolEnd of post-TAVI monitoring period (approximately Month 2)

To facilitate complete success with post-discharge monitoring in \> 80% of recruited and eligible participants (wearing monitor on same day as discharge for at least one week).

Feasibility: Timeliness of medical assessment of participants with "serious" arrhythmia identified on monitor pre-TAVIEnd of pre-TAVI monitoring period (Day 14)

To have 80% rate of medical assessment within 24 hours for any recruited and eligible patients with identified "serious" arrhythmia pre-TAVI.

Feasibility: Timeliness of medical assessment of participants with "serious" arrhythmia identified on monitor post-TAVIEnd of post-TAVI monitoring period (approximately Month 2)

To have 80% rate of medical assessment within 24 hours for any recruited and eligible patients with identified "serious" arrhythmia post-TAVI.

Patient Experience Questionnaire30-day follow-up

Survey of patient experience related to shortened length of hospital stay due to remote ECG monitoring via loop monitor and experience of care given when there are clinical findings on loop monitor

Clinical Team Experience Questionnaire30-day follow-up

Survey of clinical team experience related to implementation of a new clinical pathway for pre- and post-procedure care of TAVI patients.

Time from identification of findings on remote monitor to clinical team activation for pre-TAVI findings.End of pre-TAVI monitoring period (Day 14)

Time from when a finding is noted on remote monitor to the time the clinical team is activated to assess and intervene with the participant.

Number of participant or clinical team activations based on monitor findings pre-TAVIEnd of pre-TAVI monitoring period (Day 14)

Total number of clinical team and participant activations, along with a) Inappropriate clinical team and participant activations - clinical team is activated but no patient intervention is undertaken and b) Inappropriate negative activations - arrhythmia event is seen on loop monitoring but clinical team is not activated.

Number of participant or clinical team activations based on monitor findings post-TAVIEnd of post-TAVI monitoring period (approximately Month 2)

Total number of clinical team and participant activations, along with a) Inappropriate clinical team and participant activations - clinical team is activated but no patient intervention is undertaken and b) Inappropriate negative activations - arrhythmia event is seen on loop monitoring but clinical team is not activated.

Time from identification of findings on remote monitor to clinical team activation for post-TAVI findings.End of post-TAVI monitoring period (approximately Month 2)

Time from when a finding is noted on remote monitor to the time the clinical team is activated to assess and intervene with the participant.

Secondary Outcome Measures
NameTimeMethod
New onset of advanced AVB pre-TAVIEnd of pre-TAVI monitoring period (Day 14)

Defined as 2:1 second-degree or higher AVB.

Hospital length of stay post-TAVIMonth 2 (approximate, dependent on scheduling of TAVI procedure)

Duration of hospitalization post-TAVI procedure.

Arrhythmia-related unplanned re-hospitalization30-day post-TAVI follow-up assessment

Unscheduled hospitalization or prolongation of hospitalization for heart rhythm reasons or PPM insertion pre- or post-TAVI.

New onset paroxysmal AF post-TAVIEnd of post-TAVI monitoring period (approximately Month 2)

Defined as any irregular atrial rhythm with absence of consistent P waves lasting \> 6 seconds.

New onset of advanced AVB post-TAVIEnd of post-TAVI monitoring period (approximately Month 2)

Defined as 2:1 second-degree or higher AVB.

New onset paroxysmal AF pre-TAVIEnd of pre-TAVI monitoring period (Day 14)

Defined as any irregular atrial rhythm with absence of consistent P waves lasting \> 6 seconds.

New onset atrial tachycardia pre-TAVIEnd of pre-TAVI monitoring period (Day 14)

Defined as period of sudden rapid and regular atrial rhythm with identifiable P waves.

New onset atrial tachycardia post-TAVIEnd of post-TAVI monitoring period (approximately Month 2)

Defined as period of sudden rapid and regular atrial rhythm with identifiable P waves.

New onset NSVT pre-TAVIEnd of pre-TAVI monitoring period (Day 14)

Defined as runs of \>/= 3 ventricular beats at a heart rate of \> 100 bpm lasting \< 30 seconds.

New onset NSVT post-TAVIEnd of post-TAVI monitoring period (approximately Month 2)

Defined as runs of \>/= 3 ventricular beats at a heart rate of \> 100 bpm lasting \< 30 seconds.

New sustained VT pre-TAVIEnd of pre-TAVI monitoring period (Day 14)

Defined as ventricular runs lasting \>/= 30 seconds.

New sustained VT post-TAVIEnd of post-TAVI monitoring period (approximately Month 2)

Defined as ventricular runs lasting \>/= 30 seconds.

Severe bradycardia pre-TAVIEnd of pre-TAVI monitoring period (Day 14)

Defined as heart rate \< 40 bpm.

Severe bradycardia post-TAVIEnd of post-TAVI monitoring period (approximately Month 2)

Defined as heart rate \< 40 bpm.

New onset persistent LBBBMonth 2 (approximate, dependent on scheduling of TAVI procedure)

Defined as new onset LBBB after TAVI that persisted at hospital discharge.

Total hospitalization days up to 30 days post-TAVI30-day post-TAVI follow-up

Number of days in hospital after discharge from TAVI procedure.

Temporary PM required post-TAVIMonth 2 (approximate, depending on scheduling of TAVI procedure)

Temporary PM not removed within 4 hours of completion of leaving procedure room.

Total number of PPM implantations30-day post-TAVI follow-up

Total number of PPM implantations that are either planned (if the inciting heart rhythm was identified on monitor and implantation of PPM was arranged) or unplanned (if the monitor was not the initiating factor).

Emergency Department (ED) Visits30-day post-TAVI follow-up

Number of ED visits.

Health care utilization costs30-day post-TAVI follow-up

Costs associated with length of stay, ED use, re-admission to hospital and outpatient clinic visits will be calculated.

Syncope requiring medical assessment30-day post-TAVI follow-up

Any incident of syncope that requires medical assessment.

Trial Locations

Locations (1)

Hamilton Health Sciences Corporation - Hamilton General Hospital

🇨🇦

Hamilton, Ontario, Canada

© Copyright 2025. All Rights Reserved by MedPath