Modified Trabeculectomy for Glaucoma Surgery
- Conditions
- IOP Decreased
- Interventions
- Procedure: MODIFIED TRABECULECTOMY
- Registration Number
- NCT04019210
- Lead Sponsor
- Assiut University
- Brief Summary
A combination of hypotony, flat anterior chamber and choroidal detachment is the most common complications after filtering surgery. The purpose of this study is to present a new modification in standard trabeculectomy technique to reduce such complications.
- Detailed Description
Recta-angular scleral flap (one half the scleral thickness) is dissected,reaching 2 mm into the cornea. The dissection through the cornea is carried out with great care, leaving only thin corneal stroma over Descement's membrane.
Application of direct heat cautery using a prob Imm in size (the prob was heated for 45 seconds) the cautery was applied at 4 points two of them just in front of blue corneal line and the other two at 2 mm anterior to the blue line, the diameter of each point is 1 - 1.5 mm. The horizontal distance between each point is 3.5 mm Figure(1). The application of the cautery continue till the color of the tissue becomes brown.
Then with aid of a 23-gauge needle we penetrate these cauterized points to create 4 holes, each of them is nearly 0.3-0.5 mm in length (the opening of each hole takes the shape of a slit). Through one of these holes iridectomy is done.
These holes drain the aqueous under the scleral flap with anatomical preservation of tissue in between.
Close the scleral flap by two 10-0 nylon suture.
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 17
- 1ery glacouma
- Previous surgery
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description MODIFIED TRABECULECTOMY MODIFIED TRABECULECTOMY Recta-angular scleral flap (one half the scleral thickness) is dissected,reaching 2 mm into the cornea. The dissection through the cornea is carried out with great care, leaving only thin corneal stroma over Descement's membrane. Application of direct heat cautery using a prob Imm in size (the prob was heated for 45 seconds) the cautery was applied at 4 points two of them just in front of blue corneal line and the other two at 2 mm anterior to the blue line, the diameter of each point is 1 - 1.5 mm.
- Primary Outcome Measures
Name Time Method IOP 6 month Decreased IOP with normal depth anterior chamber measured by Tonopen
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Assiut U
🇪🇬Assiut, Egypt