Qualitative & Quantitative Comparison of Hydrostatic vs Vacuum Casting Methods in Trans-Tibial Amputees
- Conditions
- Hydrostatic Vacuum Casting
- Interventions
- Other: vacuum castingOther: hydrostatic casting
- Registration Number
- NCT03891017
- Lead Sponsor
- Loma Linda University
- Brief Summary
The purpose of this graduate research study is to compare hydrostatic and vacuum casting techniques using patient mobility indicators, volume displacement, comfort, and overall satisfaction outcomes in trans-tibial amputees.
- Detailed Description
Visit 1
* Informed Consent
* Subject will be casted using both the hydrostatic and vacuum system techniques
Visit 2 (7-10 days after Visit 1)
* One of two sockets will be randomly assigned and fitted/aligned by investigators
* Subject will be asked to perform a Timed Up and Go Test followed by a Six-Minute Walk Test
* Subject will fill out a comfort questionnaire for the prosthesis worn
Visit 3 (7 to 10 days after Visit 2)
• Subject will be asked to do the same testing as you performed in Visit 2
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 7
Not provided
Not provided
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- CROSSOVER
- Arm && Interventions
Group Intervention Description vacuum casting vacuum casting Vacuum casting will be performed using the Ottobock vacuum casting system. For our vacuum casting procedures, we will be following the protocols outlined in the Harmony Fabrication Quick Guide hydrostatic casting hydrostatic casting For the aqua casting system, we will be using an in-house manufactured device. This device will be created following guidelines from the PCAST Technical Manual
- Primary Outcome Measures
Name Time Method Six-Minute Walk Test between 7-10- days after study enrollment Participants will walk in a 100-ft hallway on a flat, hard surface in a period of 6 minutes.
- Secondary Outcome Measures
Name Time Method Six-Minute Walk Test between 14-20 days after study enrollment Participants will walk in a 100-ft hallway on a flat, hard surface in a period of 6 minutes.
Volume Calculation between 14-20 days after study enrollment The Ohio Willow Wood Omega Tracer 3-dimensional image capture device and associated Omega shape capture software will be used to determine the volumes of each socket type, comparing the vacuum and aqua casting volume metrics. The scanning variables of width, depth, and length will determine the total displacement of each socket type. It has been determined that laser scanning is a valid and reliable method for accurately measuring volume fluctuations between casting methods.
Trial Locations
- Locations (1)
Loma Linda Universtiy
🇺🇸Loma Linda, California, United States