Assessing the Accuracy of the Butterfly Sensor With RevK Version for Non-Invasive Hemoglobin Monitoring

University of California, San Francisco1 site in 1 country9 target enrollmentStarted: January 2014Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Terminated
Enrollment
9
Locations
1
Primary Endpoint
The primary purpose of this study is to assess the accuracy of the newly released Masimo SpHb Butterfly Sensor with RevK version and compare the results to a blood hemoglobin level.

Study Overview

Brief Summary

The primary purpose of this study is to assess the accuracy of the newly released Masimo SpHb Butterfly Sensor with RevK version and compare the results to a blood hemoglobin level analyzed in the UCSF Clinical Laboratories. A secondary purpose is to assess the blood hemoglobin using the Masimo Pronto-7 hand-held device immediately prior to surgery.

Detailed Description

  • Masimo SpHb™ continuous hemoglobin monitoring The Masimo SpHb™ monitor with the Butterfly Sensor with RevK version will be used to continuously monitor hemoglobin electronically. The Butterfly Sensor will be connected to the 3rd or 4th finger on either the right or left hand.
  • Masimo Pronto-7™ intermittent hemoglobin monitoring The Masimo Pronto-7™ is a hand-held, noninvasive device used for intermittent measuring of blood hemoglobin. The device is connected to a re-usable sensor which is clipped onto a finger for quick spot-check readings. A reading from the Pronto-7 will be taken immediately before surgery.
  • Blood sampling for hemoglobin determination For the study, about a ½ tsp of blood will be collected from the arterial line placed for the purpose of surgery approximately every hour during the surgery to obtain a hemoglobin measurement to be analyzed in the UCSF Clinical Lab.

Study Design

Study Type
Observational
Observational Model
Cohort
Time Perspective
Prospective

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Male of non-pregnant female 18 y/o or older
  • American Society of Anesthesiologists Classification 1,2 or 3
  • Scheduled to undergo spine or hip surgery

Exclusion Criteria

  • Pregnant or nursing
  • Patients who in the investigators clinical judgement would not be suitable for research

Outcomes

Primary Outcomes

The primary purpose of this study is to assess the accuracy of the newly released Masimo SpHb Butterfly Sensor with RevK version and compare the results to a blood hemoglobin level.

Time Frame: During surgery

Secondary Outcomes

No secondary outcomes reported