跳至主要内容
临床试验/NCT04631809
NCT04631809已完成不适用

Computer tomoGRaphy guidEd invasivE Coronary Angiography in patiEnts With a Previous Coronary Artery Bypass Graft Surgery Trial

University Hospital of Patras2 个研究点 分布在 1 个国家目标入组 225 人开始时间: 2020年10月30日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
225
试验地点
2
主要终点
Total volume of contrast administered

研究概览

简要总结

This randomized, multi-center, prospective study seeks to compare the conventional invasive Coronary Angiography with the recently described method of performing CT-Coronary Angiography prior to the invasive Coronary Angiography, in post - CABG patients subjected to coronary angiography or percutaneous coronary intervention.

详细描述

Conventional invasive coronary angiography is currently used to depict coronary arteries, however in recent years, the use of CT-coronary angiography has emerged in the literature for being a non-invasive and well tolerated examination, with imaging findings often equivalent to standard coronary angiography, especially for imaging grafts in patients undergone coronary artery bypass graft surgery (CABG).

These patients present with complex anatomy of the coronary arteries making invasive coronary angiography a demanding and time-consuming examination in which the patient is exposed to large doses of radiation and volume of contrast.

Multislice computed tomography shows high diagnostic accuracy in the detection of obstruction of the grafts while the advancement of technology continuously improves the diagnostic accuracy of the imaging findings. Of course, axial coronary angiography is more sensitive and specialized in the imaging of grafts, compared to the native coronary arteries of the heart.

Therefore, the use of CT-coronary angiography before performing the respective invasive procedure is believed that it may reduce the overall duration of the procedure, the radiation received by the patient and the amount of contrast administered.

The aim of the present study is to compare the performance of CT-coronary angiography before invasive coronary angiography compared with the performance of invasive coronary angiography alone. Τhe extent to which the information obtained from CT-coronary angiography contributes to the guidance of invasive coronary angiography that will follow will be studied, regarding the total procedure time, the volume of the contrast administered the radiation to which the patient is exposed and the patient's course over a period of 30 days.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Prevention
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Prior CABG-operation
  • Age>18 years
  • Indication for coronary angiography
  • Informed consent

排除标准

  • NSTEMI very high risk or high risk (GRACE score >140, dynamic new ST/T ECG changes)
  • Hemodynamic instability
  • High probability of patient's non-compliance with the study's procedures.
  • Severe kidney disease with GFR<30 mL/min/1.73m2
  • Known allergic reaction to contrast
  • Uncontrolled Arrhythmias (mostly afib) with heart rate over 80 bpm or frequent ectopic beats which could affect the ECG-gated cCTA protocol.

结局指标

主要结局

Total volume of contrast administered

时间窗: Immediately post-procedurally

次要结局

  • Number of catheters used(Immediately post-procedurally)
  • Total Procedure time (coronary angiography and possible angioplasty)(Immediately post-procedurally)
  • Rate of complications related to coronary angiography (aortic dissection, coronary artery dissection, stroke, bleeding, puncture site complication)(1-6 hours)
  • Overall diagnostic accuracy of CTCA for estimation of graft patency will be measured, using sensitivity, specificity, positive predictive value and negative predictive value.(Immediately post-procedurally)
  • Total Radiation Dose (Effective Dose) during coronary angiography(Immediately post-procedurally)
  • Total Fluoroscopy time(Immediately post-procedurally)
  • Number of catheters used during coronary angiography(Immediately post-procedurally)
  • Total Radiation Dose (Effective Dose)(Immediately post-procedurally)
  • Patient survival after procedure and occurrence of major adverse cardiovascular events (MACEs). (Death, hospitalization for cardiovascular reason, re-infarction, need for revascularization, stroke).(30 days)
  • Rate of patient survival after procedure and occurrence of major adverse cardiovascular events (MACEs). (Death, hospitalization for cardiovascular reason, re-infarction, need for revascularization, stroke)(3-5 days)
  • Rate of contrast induced nephropathy defined as increase of serum Cr of 25% or more, or an absolute increase of 0.5 mg/dl or more from baseline value, at 48-72 h following the exposure to contrast medium.(3-5 days)
  • Total volume of contrast agent administered during coronary angiography(Immediately post-procedurally)

研究者

发起方
University Hospital of Patras
申办方类型
Other
责任方
Principal Investigator
主要研究者

Grigorios Tsigkas

assistant Professor of Cardiology

University Hospital of Patras

研究点 (2)

Loading locations...

相似试验