Nasal Intermittent Positive Pressure Ventilation Versus Bi-level Nasal Continuous Positive Airway Pressure Following Extubation in Infants ≤ 1250 g Birthweight
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 140
- 试验地点
- 1
- 主要终点
- Rate of extubation failure
研究概览
简要总结
Mechanical ventilation is important in the care of preterm infants with respiratory failure, but may be associated with lung injury. Efforts are needed to avoid or minimize the use of mechanical ventilation. However, there is no consensus on the best non-invasive ventilation mode after extubation in preterm infants.
Objective: To compare the effectiveness of nasal intermittent positive pressure ventilation (NIPPV) versus bi-level nasal continuous positive airway pressure (BIPAP) following extubation in preterm infants ≤ 1250 g birthweight.
详细描述
In this study , mechanically ventilated preterm infants with birthweight ≤1250 g will screen for eligibility. Infants with major congenital malformations, neuromuscular disease and lack of parental consent were excluded. Enrolled infants will randomize into two study groups (NIPPV group and BIPAP group) following the decision to extubate by using sealed opaque envelopes. Extubation criteria are; loaded with caffeine according to standard clinical protocol, satisfactory blood gases (pH of more than 7.25), mean airway pressure of 7 cm water or less, fractional inspired oxygen concentration of 35 % or less and good respiratory effort.
Non-invasive respiratory support will deliver using the device of SLE 5000 (Specialised Laboratory Equipment, South Croydon, United Kingdom) in NIPPV group and infant flow- deriver device (Viasys Corp, Care Fusion, CA) in BIPAP group. The short binasal prongs will use as interface. The initial ventilator parameters for NIPPV were: PIP levels set 2 cm H2O above the pre-extubation PIP, PEEP: 5 cm H2O, rate the same as was being given before extubation and for BiPAP were: lower CPAP levels 4 to 6 cmH2O (maximum 7 cmH2O) and higher CPAP levels 8 to 9 cmH2O (maximum 10 cmH2O), Thigh 0.5-0.6 second, and a pressure exchange rate of 20-30/ minute, with the lowest adjusted FiO2 to maintain an oxygen saturation of 90% to 95%.
Extubation failure was defined as: development of respiratory acidosis (blood gases with pH < 7.2 and PaCO2> 60 mmHg), or hypoxemia (blood gases with PaO2 < 50 mmHg despite oxygen supplementation of 60 percent), or severe apnea requiring mask ventilation.
Surfactant requirement is goingto evaluate in all infants after NICU admission. Poractant alfa was administered if necessary.
The primary end-point, rate of extubation failure within 96 hours following first extubation, will compared between the groups. Short and long-term neonatal outcomes will also evaluate.
研究设计
- 研究类型
- Interventional
- 分配方式
- Randomized
- 干预模型
- Parallel
- 主要目的
- Supportive Care
- 盲法
- None
入排标准
- 年龄范围
- 1 Day 至 14 Days(Child)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Mechanically ventilated preterm infants with birthweight ≤1250 g
排除标准
- •Infants with major congenital malformations, neuromuscular disease and lack of parental consent
研究组 & 干预措施
BIPAP
BIPAP after ekstubation
NIPPV
NIPPV after ekstubation
干预措施: NIPPV (Device)
结局指标
主要结局
Rate of extubation failure
时间窗: within 96 hours
次要结局
未报告次要终点
研究者
nilüfer okur
NEONATOLOGY
Zekai Tahir Burak Women's Health Research and Education Hospital