New Fabric Attenuation Device in Endovascular Interventional Radiology (PREFER)

Completed
Conditions
Exposure
Registration Number
NCT01450969
Lead Sponsor
Baptist Health South Florida
Brief Summary

The PREFER Trial primary objective of the trial is to show how much radiation attenuation is provided by XPF in absolute and relative terms.

Detailed Description

The PREFER Trial has three main objectives. The primary objective of the trial is to show how much radiation attenuation is provided by XPF in absolute and relative terms. The secondary objective of the study is to measure and compare the amount of radiation that interventional radiologists are exposed to per case in an interventional suite setting using FDA approved XPF thyroid collars or standard 0.5 mm Pb equivalent thyroid collars. The third objective is to assess the operator comfort wearing the XPF protection devices. In order to achieve these objectives, measurements will be performed in 60 consecutive endovascular procedures requiring C-arm fluoroscopy performed at BCVI. Participants will be asked to wear an XPF cap (weighing approximately 100 grams) in every study procedure. Furthermore, a prospective randomization will be performed, assigning participants to wear their own standard 0.5 mm Pb equivalent thyroid collar or to wear the FDA approved XPF thyroid collar. Radiation exposure will be monitored with 4 radiation detectors (TLDs, 2 attached to the cap, 2 attached to the collar) which the participant is required to wear. After each procedure the participant will be asked to rate the comfort of wearing the devices on a scale from 1 to 100.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
60
Inclusion Criteria
  • Interventional Radiologists practicing in Baptist Cardiac & Vascular Institute
  • consecutive endovascular procedure requiring C-arm fluoroscopy
Exclusion Criteria
  • Interventional Neuroradiologists and Interventional Cardiologists will not be included in this study.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Radiation attenuation in percentage (%) and in absolute terms (μSv/min)The attenuation is assessed directly after each procedure (day 1)

The null hypothesis is that the XPF thyroid collar is inferior to the standard 0.5mm Pb lead equivalent thyroid collar with regard to radiation attenuation/transmission. The alternative hypothesis is that the XPF thyroid collar is non-inferior to the standard thyroid collar. If there is truly no difference between standard and XPF thyroid collars, then 60 patients are required to be 95% sure that the lower limit of a one-sided 95% confidence interval (or equivalently a 90% two-sided confidence interval) will be above the non-inferiority limit of -0.7% transmission rate and -0.013 μSv/min.

Secondary Outcome Measures
NameTimeMethod
Wearing comfort of the XPF cap and collar on a scale from 0-100.(day 1) Operators are asked directly after each procedure to rate the wearing comfort

Trial Locations

Locations (1)

Baptist Hospital of Miami, Miami Cardiac and Vascular Institute

🇺🇸

Miami, Florida, United States