Skip to main content
Clinical Trials/NCT01787929
NCT01787929
Completed
Not Applicable

Cemented Versus Uncemented Hemiarthroplasty for Displaced Femoral Neck Fracture in Elderly Patient : a Randomized Prospective Trial

Centre Hospitalier Universitaire de Nice1 site in 1 country170 target enrollmentFebruary 7, 2016

Overview

Phase
Not Applicable
Intervention
Not specified
Conditions
Femoral Neck Fractures
Sponsor
Centre Hospitalier Universitaire de Nice
Enrollment
170
Locations
1
Primary Endpoint
Functionality
Status
Completed
Last Updated
3 years ago

Overview

Brief Summary

The purpose of this study was to identify the clinical relevance of cementless hemiarthroplasties, compare Harris functional score.The hypothesis is the non-inferiority of cementless hemiarthroplasties compare cemented hemiarthroplasties in order to justify the relevance of cementless hemiarthroplasties in displaced femoral neck fractures.

150 patients will be included, 75 with cemented hemiarthroplasty and 75 with uncemented hemiarthroplasty. They will be followed during one year after the surgery, with a functionality assessment at 3 month and 12 month.

Detailed Description

Most subcapital femoral neck fractures occur in the elderly population and are the result of low-energy trauma. Return of the patient to prefracture level of function usually can best be accomplished with surgery. Nonsurgical management has resulted in an excessive rate of medical morbidity and mortality. The overall 1-year mortality rate after hip fracture in the elderly ranges from 14% to 36%. Prosthetic replacement has been favored for the treatment of displaced femoral neck fractures in the frail, elderly population with multiple medical comorbidities because of the challenges of achieving stable proximal fragment fixation in osteopenic bone, and the need for early, full weight-bearing mobilization. Failure rates of 30% to 40% have been consistently reported over multiple series over the past few decades in elderly patients with displaced femoral neck fractures treated with internal fixation. Once prosthetic arthroplasty has been chosen, further controversy surrounds the type of fixation, cemented or cementless. Good to excellent results can be expected with either cemented or cementless newer generation arthroplasties. Risks of cementless arthroplasty include femoral fracture, prosthesis subsidence, and anterior thigh pain. Cementation of the prosthesis places the patient at risk for intraoperative death or embolization of marrow content during cementation. The aim of the study is to assess the clinical relevance of a collared uncemented stem compared with use of cemented stem in elderly population with displaced femoral neck fracture. A randomised trial will include 150 patients with an acute displaced femoral neck fracture in an elderly population. All patient will give informed consent, and the research protocol is approved by the regional ethics committee. The inclusion criteria are an age of at least 70 years old, a displaced femoral neck fracture (Garden stage III or IV), an ASA grade\< 4, ambulatory and non cognive impairment patients. Clinical and radiographic examinations will be perform at perioperative period, at 3 and 12 month after surgery. The main outcome measures will be functional score, pain, mobility, complications, reoperations, activity of daily living, quality of life, strenght, and radiolographic subsidence. The primary hypothesis of this study is that use of a collared uncemented stem would not provide an improvement in functional outcome compared with use of cemented stem in elderly population with displaced femoral neck fracture.

Registry
clinicaltrials.gov
Start Date
February 7, 2016
End Date
March 11, 2020
Last Updated
3 years ago
Study Type
Interventional
Study Design
Parallel
Sex
All

Investigators

Responsible Party
Sponsor

Eligibility Criteria

Inclusion Criteria

  • displaced femoral neck fractures (Garden III and IV)
  • 70 year old or more
  • ASA score \< or = III
  • Lee score \< or = 2

Exclusion Criteria

  • Parker score \<4
  • pathological femoral neck fracture ( paget disease or tumor)

Outcomes

Primary Outcomes

Functionality

Time Frame: Changes at 3 and 12 month post-operative

Functionality will be assessed at 3 and 12 month after surgery by Harris test scoring.

Study Sites (1)

Loading locations...

Similar Trials

Recruiting
Not Applicable
Cemented versus non-cemented hemiarthroplasty of the hip as a treatment for a displaced femoral neck fracture; a multi center randomised trial.hemiarthroplastykophalsprothesecementcementlessongecementeerdfemoral neck fracturemediale collum fractuur
NL-OMON22861The study will be conducted at the Orthopaedic Departments of: -Reinier de Graaf Gasthuis Delft-Ziekenhuis Rijnstate Arnhem -Canisius Wilhelmina Ziekenhuis Nijmegen -Elisabeth Ziekenhuis Tilburg.200
Completed
Not Applicable
CEMENTED VERSUS NON CEMENTED HEMIARTHROPLASTY OF THE HIP AS A TREATMENT FOR A DISPLACED FEMORAL NECK FRACTURE; A RANDOMISED TRIAhip fracture10005944
NL-OMON39179Reinier de Graaf Groep200
Completed
Not Applicable
Uncemented Hemiarthroplasty, Radiological Features Comparing Lateral Versus Anterolateral ApproachFemoral Neck FracturesHemiarthroplastyHeterotopic Ossification
NCT03974698Sorlandet Hospital HF150
Enrolling By Invitation
Phase 1
The outcomes of cementless bipolar hemiarthroplasty vs total hip arthroplasty in elderly fracture neck of femurElderly femoral neck fractureHip arthroplastyBipolar hemiarthroplastyTotal hip arthroplastyFunctional outcomesDislocation ratesRevision ratesOperative timeIntra&#45operative blood lossElderly femoral neck fractureFracture neck of femurHip arthroplastyHip replacementBipolar hemiarthroplastyTotal hip arthroplasty
TCTR20201222002Orthopedics department76
Unknown
Not Applicable
A Prospective Randomized Trial of Uncemented Versus Cemented Hemiarthroplasty for Displaced Femoral Neck FracturesFemoral Neck Fractures
NCT00491673Ullevaal University Hospital230