跳至主要内容
临床试验/NCT03852329
NCT03852329终止不适用

Feasibility of Stereotactic Image Guidance on the Lateral Skull Base

Insel Gruppe AG, University Hospital Bern2 个研究点 分布在 1 个国家目标入组 3 人开始时间: 2020年1月1日最近更新:
适应症

试验速览

阶段
不适用
状态
终止
入组人数
3
试验地点
2
主要终点
Quantitative accuracy

研究概览

简要总结

A clinical trial to asses the accuracy, usefulness and usability of a stereotactic image-guidance system during lateral skull base surgery.

详细描述

Stereotactic image guidance aims to provide for accurate and precise instrument localization in patient-specific image data. Image guidance is effectively used in various surgical domains such as neurosurgery, nose-surgery and orthopaedic surgery with benefits for patients such as less invasiveness and reduced surgery time. Its application for lateral skull base surgery was proposed and is considered an unmet clinical need. However, the small geometric scale (~0.5 mm) of the anatomical structures within the lateral skull base prevents the effective application of commercially available systems due to their insufficient guidance accuracy. Within the context of robotic cochlear implantation, stereotactic image guidance technology with a guidance accuracy <0.5 mm was developed. The aim of this study is to apply the developed technology in lateral skull base surgery other than robotic cochlear implantation.

This study primarily seeks to determine the effective end-to-end image guidance accuracy of the investigational device at predefined artificial landmarks on a task-specific registration device attached to the skull.

The main secondary objective is to qualitatively assess the available accuracy at predefined anatomical landmarks by visual inspection through surgeons in the absence of quantifiable ground truth information.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients which are regularly scheduled for an otologic surgical procedure
  • Informed Consent as documented by signature
  • Age >= 18 years

排除标准

  • Other clinically condition or disease that would (as deemed by the operating surgeon) significantly increase the risk of surgery

结局指标

主要结局

Quantitative accuracy

时间窗: Until the end of the intervention, expected to be up to 4.5 hours

The primary endpoint is the localization accuracy of predefined artificial target positions on the registration tripod measured in millimetres. The tracked instrument is positioned on the target positions. The Euclidean distance between the location of the instrument in the image data as indicated by the stereotactic image guidance system and to the true location of the target point in the image data is measured. The true location of the target points in the image data is determined by alignment of the 3D model of the tripod (including the known target positions on the tripod) with the image data.

次要结局

  • Qualitative accuracy(Until the end of the intervention, expected to be up to 4.5 hours)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验