Effects of Individualized Positive End-expiratory Pressure (PEEP) on Intrinsic PEEP and Stroke Volume During One-lung Ventilation: a Single-center, Randomized Crossover Study
试验速览
- 阶段
- 不适用
- 状态
- 招募中
- 入组人数
- 48
- 试验地点
- 1
研究概览
简要总结
This study investigates the effects of three extrinsic PEEP settings-5 cmH2O, 0 cmH2O, and an individualized PEEP (70% of the measured intrinsic PEEP)-on intrinsic PEEP and hemodynamic stability in patients with intrinsic PEEP undergoing lung resection surgery, using a randomized, crossover design.
详细描述
Intrinsic positive end-expiratory pressure (iPEEP) frequently occurs during one-lung ventilation (OLV), which is essential for lung resection. This occurrence is driven by three primary factors. First, a significant portion of patients undergoing lung surgery have concomitant chronic obstructive pulmonary disease (COPD) and thus possess a baseline intrinsic PEEP. Second, high-frequency ventilation applied to prevent carbon dioxide accumulation during OLV shortens the expiratory time, thereby generating intrinsic PEEP. Third, the use of a narrow-bore double-lumen endobronchial tube for OLV increases airway resistance, accelerating the development of intrinsic PEEP. Intrinsic PEEP causes lung hyperinflation and elevates intrathoracic pressure, which can subsequently decrease venous return and lead to abrupt hypotension. However, research remains insufficient regarding the optimal level of extrinsic PEEP for patients who develop intrinsic PEEP during OLV. While an extrinsic PEEP of around 5 cmH2O is generally applied during OLV, some guidelines recommend completely removing extrinsic PEEP (0 cmH2O) during OLV in COPD patients. Nevertheless, this recommendation lacks robust scientific evidence. Furthermore, whether the strategy of setting extrinsic PEEP at approximately 70% of intrinsic PEEP-as suggested by studies in critically ill patients-is equally valid in the intraoperative OLV environment remains unverified. Theoretically, if extrinsic PEEP exceeds intrinsic PEEP, it may exacerbate lung hyperinflation by increasing expiratory resistance. Conversely, an extrinsic PEEP that is too low may cause airway collapse during expiration, paradoxically worsening gas trapping. Therefore, this study aims to evaluate the effects of three extrinsic PEEP settings-5 cmH2O, 0 cmH2O, and an individualized PEEP (70% of the measured intrinsic PEEP)-on intrinsic PEEP and hemodynamic stability using a randomized, crossover design.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
盲法说明
Although all patients will receive three interventions, the order of intervention will be randomly determined. The order of interventions will be blinded to participants, the investigators, and the outcome assessor.
入排标准
- 年龄范围
- 19 Years 至 100 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •American Society of Anesthesiologists Physical Status I - III
- •The Eastern Cooperative Oncology Group Performance Status Grade 0 - 2
- •Lung resection surgery requiring one-lung ventilation for over 60 minutes
- •Indication of double-lumen endobronchial tube (female 35 Fr, male 37 Fr)
- •Patient who is diagnosed with intrinsic PEEP during one-lung ventilation
排除标准
- •Large bullae
- •Emergency surgery
- •Mechanical ventilation before surgery
- •Hemodynamic instability before surgery
- •Surgery requiring cardiopulmonary bypass
- •Pregnancy, breastfeeding patient
- •Patient's refusal to participate
- •No intrinsic PEEP during one-lung ventilation
研究组 & 干预措施
Experimental group
During one-lung ventilation, baseline intrinsic PEEP and stroke volume will be measured. All participants will receive three PEEP interventions: 0 cmH2O, 5 cmH2O, and 70% of the intrinsic PEEP value. The order of interventions is randomized. Each intervention will be maintained for 5 minutes, with a 5-minute washout period between interventions to minimize mutual interference. At the end of each intervention, two primary outcomes (intrinsic PEEP and stroke volume) will be measured.
干预措施: PEEP0 (Procedure)
Experimental group
During one-lung ventilation, baseline intrinsic PEEP and stroke volume will be measured. All participants will receive three PEEP interventions: 0 cmH2O, 5 cmH2O, and 70% of the intrinsic PEEP value. The order of interventions is randomized. Each intervention will be maintained for 5 minutes, with a 5-minute washout period between interventions to minimize mutual interference. At the end of each intervention, two primary outcomes (intrinsic PEEP and stroke volume) will be measured.
干预措施: PEEP5 (Procedure)
Experimental group
During one-lung ventilation, baseline intrinsic PEEP and stroke volume will be measured. All participants will receive three PEEP interventions: 0 cmH2O, 5 cmH2O, and 70% of the intrinsic PEEP value. The order of interventions is randomized. Each intervention will be maintained for 5 minutes, with a 5-minute washout period between interventions to minimize mutual interference. At the end of each intervention, two primary outcomes (intrinsic PEEP and stroke volume) will be measured.
干预措施: PEEPi (Procedure)
研究者
Hyun Joo Ahn
Anesthesiologist, Professor
Samsung Medical Center
