跳至主要内容
临床试验/NCT00318565
NCT00318565已完成4 期

Navistar Thermocool Evaluation of the Catheter With the Stockert 70 Radiofrequency Generator for Endocardial Ablation in Patients With Typical Atrial Flutter

Biosense Webster, Inc.46 个研究点 分布在 1 个国家目标入组 291 人开始时间: 2006年1月最近更新:
适应症

试验速览

阶段
4 期
状态
已完成
入组人数
291
试验地点
46
主要终点
Percentage of Subjects With Complete Bidirectional Conduction Block.

研究概览

简要总结

The primary objective is to provide additional corroborative safety and efficacy data for the Navistar Thermocool catheter for the treatment of subjects with typical atrial flutter (AFL).

详细描述

This study is a prospective, non-randomized, single-arm, multi-center condition of approval evaluation. The device is currently FDA approved for commercial distribution. Subjects with symptomatic typical atrial flutter will be considered for the condition of approval study. This study will be conducted at up to 30 centers in a minimum of 221 evaluable subjects.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Two symptomatic episodes of typical atrial flutter (or chronic atrial flutter) during the one-year period prior to enrollment. This may include typical AFL occurring while receiving anti-arrhythmic drug (AAD) therapy for non-AFL tachyarrhythmia, including atrial fibrillation.
  • At least one episode of typical (clockwise or counterclockwise) atrial flutter documented by 12 lead electrocardiogram (ECG), Holter monitor, transtelephonic event monitor, telemetry strip, or implanted device within 6 months prior to enrollment.
  • 18 years of age or older
  • Informed consent

排除标准

  • Intracardiac thrombus
  • Uncontrolled heart failure, or New York Heart Association (NYHA) class III or IV heart failure
  • Women who are pregnant
  • Cardiac surgery (ventriculotomy or atriotomy) within the past two months
  • Intra-atrial thrombus, tumor, or other abnormality that precludes catheter introduction and placement
  • Unstable angina or acute myocardial infarction within 3 months
  • Awaiting cardiac transplantation
  • Heart disease in which corrective surgery is anticipated within 6 months
  • Presence of condition that precludes appropriate vascular access
  • Enrolled in any investigational device exemption (IDE) investigating study for a device or drug
  • High risk for non-compliance with the protocol (e.g., inaccessible for follow-up by the investigator or patient's physician)
  • Radio frequency (RF) ablation for typical atrial flutter within the past 2 months

结局指标

主要结局

Percentage of Subjects With Complete Bidirectional Conduction Block.

时间窗: During the procedure

Acute success is defined as the confirmation of complete bidirectional conduction block across the subeustachian (cavo-tricuspid) isthmus. The percentage of subjects with confirmed conduction block will serve as the outcome measure.

Percentage of Subjects Experiencing Cardiovascular Specific Adverse Events (CSAE) Within Seven (7) Days of the Ablation Procedure.

时间窗: 7 Days

The cardiovascular specific adverse event (CSAE) rate is the primary safety enpoint for the study. A CSAE is an event which occurs within the first week (7 days) following use of the device and is one of the following cardiac specific adverse events: cardiac perforation, pericardial effusion, pulmonary embolus, complete heart block, stroke, acute myocardial infarction, and death.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor

研究点 (46)

Loading locations...

相似试验