MedPath

Evaluation of a Binaural Spatialization Method for Hearing Aids

Phase 2
Completed
Conditions
Sensorineural Hearing Loss
Interventions
Device: Hearing Aids
Registration Number
NCT02693704
Lead Sponsor
Sonova AG
Brief Summary

This study investigates the possible benefits of using binaural spatialization techniques in digital wireless microphone systems for hearing aids. Speech intelligibility tests, speaker localization tests and preference tests are performed. The results of a diotic (current rendering) and a binaural (suggested rendering) rendering are compared.

Detailed Description

The signal processing laboratory (LTS2) of the Swiss Federal Institute of Technology (EPFL) has developed a new feature of sound rendering in hearing aids. This is a collaboration between EPFL and the Swiss company Phonak Communications AG. The new functionality works with the range of Roger products from Phonak, a new generation of FM systems that use a digital transmission.

FM technology refers to a type of wireless system that helps people better understand speech in noisy situations. FM systems commonly work together with a user's hearing aids, although systems are also available for those with otherwise normal hearing (such as people who suffer from APD, ADHD etc.). An FM system works like this: the person speaking wears or holds a transmitter microphone, or the transmitter is placed in the middle of the group (picking up speech from all around). Using harmless radio waves, the FM system sends speech signal(s) to the listener, who wears a tiny FM receiver behind the ear.

The new feature of such systems performs processing of the speaker's speech signal so that it renders information related to their spatial location. This so-called sound "spatialization" is a natural property of the human binaural auditory system, which allows us to localize sounds. However, this sound spatialization is not delivered by the current FM systems. Thanks to the new technology from EPFL and Phonak, it is now possible to include a binaural spatialization of the speech signal in the Roger product of Phonak hearing devices.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
40
Inclusion Criteria

Not provided

Exclusion Criteria
  • History of tinnitus or hyperacusis.
  • Visual impairment, after correction with glasses or not.
  • History of chronic or terminal illness or psychiatric disturbance,.
  • History of epilepsy or other reactions associated with the proximity to a video screen.

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Profound hearing impairedHearing AidsPatients showing profound hearing loss (\> 80 dB HL). Introduction of speech signal via the DAI of two hearing aids among: PhonakAudéo V-13 Phonak Baseo Q-P, Q-SP, Q-M13 Phonak Bolero Q-P, Q-SP, Q-M13, Boléro V-P, V-SP Phonak Naida Q-CRT, Q-SP, Q-UP Phonak Sky Q-RIC, Q-SP, Q-UP, Q-M13 Phonak Ambra microP, SP, M H20 Phonak Cassia microP, SP, M H20 Phonak Dalia microP, SP, M H20 Phonak Naida S SP, S UP, S CRT Phonak Solana microP, SP, M H20 Phonak Certéna micro, Art M, Art P, Art SP, Art micro Phonak Exélia micro, Art M, Art P, Art SP, Art micro Phonak Milo Plus micro, Plus SP, Plus UP Phonak Naida SP, SP Junior, UP, UP Junior Phonak Nios micro, S H20 Phonak Versata micro, Art M, Art P, Art SP, Art micro
Moderate hearing impairedHearing AidsPatients showing moderate hearing loss (40-60 dB HL). Introduction of speech signal via the DAI of two hearing aids among: PhonakAudéo V-13 Phonak Baseo Q-P, Q-SP, Q-M13 Phonak Bolero Q-P, Q-SP, Q-M13, Boléro V-P, V-SP Phonak Naida Q-CRT, Q-SP, Q-UP Phonak Sky Q-RIC, Q-SP, Q-UP, Q-M13 Phonak Ambra microP, SP, M H20 Phonak Cassia microP, SP, M H20 Phonak Dalia microP, SP, M H20 Phonak Naida S SP, S UP, S CRT Phonak Solana microP, SP, M H20 Phonak Certéna micro, Art M, Art P, Art SP, Art micro Phonak Exélia micro, Art M, Art P, Art SP, Art micro Phonak Milo Plus micro, Plus SP, Plus UP Phonak Naida SP, SP Junior, UP, UP Junior Phonak Nios micro, S H20 Phonak Versata micro, Art M, Art P, Art SP, Art micro
Severe hearing impairedHearing AidsPatients showing severe hearing loss (60-80 dB HL). Introduction of speech signal via the DAI of two hearing aids among: PhonakAudéo V-13 Phonak Baseo Q-P, Q-SP, Q-M13 Phonak Bolero Q-P, Q-SP, Q-M13, Boléro V-P, V-SP Phonak Naida Q-CRT, Q-SP, Q-UP Phonak Sky Q-RIC, Q-SP, Q-UP, Q-M13 Phonak Ambra microP, SP, M H20 Phonak Cassia microP, SP, M H20 Phonak Dalia microP, SP, M H20 Phonak Naida S SP, S UP, S CRT Phonak Solana microP, SP, M H20 Phonak Certéna micro, Art M, Art P, Art SP, Art micro Phonak Exélia micro, Art M, Art P, Art SP, Art micro Phonak Milo Plus micro, Plus SP, Plus UP Phonak Naida SP, SP Junior, UP, UP Junior Phonak Nios micro, S H20 Phonak Versata micro, Art M, Art P, Art SP, Art micro
Normal hearingHearing AidsPeople showing no hearing loss (\< 20 dB HL). Introduction of speech signal via the DAI of two hearing aids Phonak Naida IX SP.
Primary Outcome Measures
NameTimeMethod
Speech Intelligibility1 day of the experiment

Speech recognition score (%) For each group: average of the SRS over all subjects in the group. The SRS correspond to the number of understood words in a sequence of sentences (French HINT database) mixed with several level of masking noise (speech-shaped noise). Some are played diotically, the other are spatialized in various directions. The goal is to ensure that the spatialization processing does not degrade the understanding of the speech.

Speaker's Localization1 day of the experiment

Localization error (in number of spatial sectors)

For each group: average localization error over all subjects in the group. It is the difference between the actual spatial sector and the one reported by the listeners. There were 5 spatial sectors, and 9 possible locations. For instance: if the stimuli is played in sector 4, and the listener perceives it in 2, then the localization error is \|4-2\| = 2. The goal is to compare the localization error in 3 conditions: 1/ with no hearing aids (reference of natural localization) and no spatialization 2/ with hearing aids and standard fittings and no spatialization, and 3/ with spatialization applied.

Listener's Subjective Preference1 day of the experiment

Listeners compare two audiovisual stimuli (diotic and spatialized) and Indicate their preference between binaural diotic (no spatialization), spatialized stimuli, or no preference. Results are given as the percentage of participant for the 3 possible answers in each group.

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Ecole Polytechnique Fédérale de Lausanne

🇨🇭

Lausanne, Switzerland