跳至主要内容
临床试验/NCT03715920
NCT03715920已完成不适用

Comparison of Different Quadriceps Femoris Isometric Strengthening Methods in Healthy Young Women

Pamukkale University2 个研究点 分布在 1 个国家目标入组 46 人开始时间: 2017年9月24日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
46
试验地点
2
主要终点
Isokinetic Strength measurement

研究概览

简要总结

Background:It has been reported in previous studies that more motor units are fired with electrical stimulation than voluntary muscle contraction, and even high intensity currents provide 10-30% more contractions than voluntary muscle contraction.

Objective:This study was planned to compare the effectiveness of high voltage pulsed galvanic (HVPG) stimulation, Russian current and isometric exercise on quadriceps femoris (QF) isometric muscle strength in healthy young women.

Methods:Forty-six healthy young women were included in the study (mean age=21.02 ± 1.27). Before and after the training, the dominant side QF isometric muscle strength of participants was assessed with the Isokinetic Dynamometer . The peak torque and average torques of the participants were recorded after the test. The training was planned as HVPG current for the the first group (n = 16), as Russian current for the second group (n = 15) and as isometric strengthening for the third group (n = 15). All treatments were performed under physiotherapist supervision for a total of 15 sessions for 3 days a week for 5 weeks.

详细描述

Muscle strength, Isokinetic strength measurement:

The dominant side QF isometric muscle strength (torque measurements) of the participants was assessed with the Isokinetic Dynamometer . Before the test, participants were subjected to a standard warm-up of 5 minutes and evaluations were carried out using a standard seat. The back of the seat was angled 105 ° backward to provide 75 ° flexion at the body. The knee was positioned at an angle of 60 ° and was fixed with bands around the body, waist, hip and ankle. Participants had no previous experience with isokinetic dynamometer testing, therefore; it was started with a trial whose protocols were same with QF isometric muscle strength measurement protocols. Then participants QF isometric muscle strength was measured by three 10-second maximal isometric contraction. Rest periods of 3 seconds between each contraction were given. Each participant held the sides of the seat with both hands during the test. Verbal encouragement was made throughout the whole test to obtain maximum strength from the participants. The peak torque and average torques of the participants were recorded after the test.

High Voltage Pulsed Galvanic Current:

The instrument was automatically set to a pulse rate of 100 μs while the pulse frequency was set to 60 pulses / sec. In order to avoid fatigue, the intermittant form of the current was selected and the transition time / rest time was set to 4 sec. impulse / 12 sec. The total output voltage of the device ranged from 0 to 500 volts and the current intensity was increased until the sensible contraction of the applied muscle was achieved without causing too much sense of discomfort. Stimulation was performed after the body and knee were positioned and stabilized at 75 ° flexion and 60 ° flexion angle, respectively. One of the 6 * 8 cm carbonated electrodes was placed in the distal portion of the vastus medialis, while the other one was placed in the proximal portion of the vastus lateralis. This placement was intended to stimulate a large proportion of the muscle fibers of the QF muscle.The HVPG was applied for a total of 20 minutes. Current intensity was increased to obtain optimal muscle contraction.

Russian Current In the treatment with the Russian current, a protocol developed by Kots, also known in the literature as "Russian Technique", was used. In the treatment with the Russian movement, a protocol developed by Kots, also known as "Russian Technique", was used in the literature. There were 10 muscle contractions per treatment session in this protocol. Each contraction lasted for 10 seconds and a resting time of 50 seconds were given for the next contraction (transition: rest ratio was 1/5).The position of the participants in the application and the placement of the electrodes were same as the the other application. Current intensity was increased until tetanic muscle contraction was obtained.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Sequential
主要目的
Treatment
盲法
None

入排标准

年龄范围
18 Years 至 30 Years(Adult)
性别
Female
接受健康志愿者

入选标准

  • Willingness to participate in the study.
  • Not having knee complaints such as pain, lockout, morning arrest, swelling, difficulty in walking.
  • Not having any orthopedic or neurological disability

排除标准

  • Exercising regularly for the last six months.
  • Presence of cardiovascular, pulmonary, orthopedic and neurological problems which may prevent exercise.

研究组 & 干预措施

High Voltage Pulsed Galvanic Current

Active Comparator

HVPG current is a new form of neuromuscular electrical stimulation.The total output voltage of the device ranged from 0 to 500 volts and the current intensity was increased until the sensible contraction of the applied muscle was achieved without causing too much sense of discomfort

干预措施: Electrical currents (Device)

Russian Current

Placebo Comparator

Russian currents are a high frequency current of 2500 Hz and reduce the resistance of the skin and it would penetrate deeper and reach deeper motor nerves.Russian movement, a protocol developed by Kots, also known as "Russian Technique", was used in the literature. There were 10 muscle contractions per treatment session in this protocol. Each contraction lasted for 10 seconds and a resting time of 50 seconds were given for the next contraction (transition: rest ratio was 1/5).

干预措施: Electrical currents (Device)

Isometric Exercise

Sham Comparator

Isometric or static strength training is exercises performed without joint movement and changing muscle length during muscle contraction.

The body and knee of the participants in the isometric exercise group were positioned and stabilized at 75 ° flexion and 60 ° flexion angle, respectively as in the stimulation groups. Participants were asked to do 10 repetitions as 10 seconds of maximum voluntary contractions and 10 seconds of rest.

干预措施: Electrical currents (Device)

结局指标

主要结局

Isokinetic Strength measurement

时间窗: One week

Muscle strength, Isokinetic strength measurement: The dominant side QF isometric muscle strength (torque measurements) of the participants was assessed with the Isokinetic Dynamometer (Humac Norm Testing Rehabilitation System, CSMI Medical Solutions, USA).

次要结局

  • Isometric exercise(One week)

研究者

申办方类型
Other
责任方
Principal Investigator
主要研究者

Bilge Basakci Calik

Principal Investigator

Pamukkale University

研究点 (2)

Loading locations...

相似试验