Lamellar Transplant With Lyophilized Corneas
- Conditions
- Keratoconus
- Registration Number
- NCT00409955
- Lead Sponsor
- Federal University of São Paulo
- Brief Summary
- The goals of this study are to develop a lyophilization method for anterior lamellar transplants in Brasil and to make a comparative analysis among patients transplanted with lyophilized and optisol corneas
- Detailed Description
* After the development of a techinique to lyophilize corneas, we randomly assingned 20 patients with keratoconus and visual acuity of \< 20/60, who signed the consent term and divided them into 2 groups. One group was transplanted with lyophilized corneas and the other group with optisol corneas.
* Patients are being followed for 6 months with visual acuity, refraction, topography, orbscan, pachmetry, ultrasound biomicroscopy and confocal microscopy.
* Results are going to be statistically analysed by SPSS program.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 20
- Keratoconus patient
- BCVA < 20/60
- No systemic diseases
- Who signed the inform consent
- BCVA > 20/60
- Presence of deep opacities
- Systemic diseases
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Primary Outcome Measures
Name Time Method Ultrasound Biomicroscopy Confocal Microscopy Topography Orbscan Pachmetry Masked Examiner to evaluate transparency and quality of the transplant
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Federal University of Sao Paulo
🇧🇷São Paulo, SP, Brazil