MedPath

Effect of Ventilation Mode on Lung Deposition of a Radiolabeled Aerosol During Mechanical Ventilation: Barometric Versus Volumetric

Not Applicable
Completed
Conditions
Post-operative Neurosurgery
Interventions
Device: Vibrating-mesh nebulizer
Other: Gamma scintigraphy
Other: Preoperative spirometry
Registration Number
NCT01879488
Lead Sponsor
Cliniques universitaires Saint-Luc- Université Catholique de Louvain
Brief Summary

Controlling the respiratory pattern of mechanically ventilated patients in volume control mode is recommended during nebulization. No studies looked into conditions of nebulization during assisted mechanical ventilation to define the optimal nebulization technique and its effect on pulmonary deposition.

The aim of this study is to analyse the effect of ventilation mode (barometric versus volumetric) on deposition by planar scintigraphy during mechanical ventilation.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
19
Inclusion Criteria
  • Invasive mechanical ventilation
  • Healthy lungs
Exclusion Criteria
  • Change of ventilation mode during nebulization

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Nebulization during pressure support ventilationtechnetium-99m - Diethylenetriaminepentaacetic acidPatients ventilated in pressure support mode during nebulization
Nebulization during pressure support ventilationVibrating-mesh nebulizerPatients ventilated in pressure support mode during nebulization
Nebulization during pressure support ventilationGamma scintigraphyPatients ventilated in pressure support mode during nebulization
Nebulization during pressure support ventilationPreoperative spirometryPatients ventilated in pressure support mode during nebulization
Nebulization during volume assist control modetechnetium-99m - Diethylenetriaminepentaacetic acidPatients ventilated in volume assist control mode during nebulization
Nebulization during volume assist control modeVibrating-mesh nebulizerPatients ventilated in volume assist control mode during nebulization
Nebulization during volume assist control modeGamma scintigraphyPatients ventilated in volume assist control mode during nebulization
Nebulization during volume assist control modePreoperative spirometryPatients ventilated in volume assist control mode during nebulization
Primary Outcome Measures
NameTimeMethod
Pulmonary depositionImmediately after nebulization by imaging assessment, an expected average of 30 minutes
Secondary Outcome Measures
NameTimeMethod
Penetration indexImmediately after nebulization by imaging assessment, an expected average of 30 minutes
Lung functionPreoperative assessment, the day before inclusion
Mechanical ventilation settingsDuring nebulisation time, an expected average of 15 minutes

Trial Locations

Locations (1)

Cliniques Universitaires Saint-Luc

🇧🇪

Brussels, Belgium

© Copyright 2025. All Rights Reserved by MedPath