Skip to main content
Clinical Trials/NCT01626274
NCT01626274CompletedNot Applicable

Long Term Vital Parameter Monitoring Pilot Study to Evaluate Measurement Data Via In-ear Sensor in Comparison to Standard Polysomnography in Sleep Laboratory

RWTH Aachen University2 sites in 1 country8 target enrollmentStarted: January 2012Last updated:
Conditions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
8
Locations
2
Primary Endpoint
Extraction of vital signs out of measurement data via individually formed in-ear sensor system in comparison to standard polysomnography data in sleep laboratory

Study Overview

Brief Summary

The purpose of this study is to evaluate the feasibility of non-intrusive 24 hours non-invasive measurements with minimized LAVIMO sensor system. The LAVIMO-system is a photoplethysmographic device for reflective mode measurements of the optical damping upper skin layers inside of the ear canal at two different wave lengths. It consists of the in-ear sensor, the electronics and a PC. Vital signs parameter like heart rate, heart rate variability, breathing and arterial blood oxygenation are monitored in patients with sleep apnoea and compared to measurements of standard polysomnography of these patients during one night in the sleep laboratory.

Detailed Description

In 20 patients who routinely have to undergo a polysomnographic night in sleep laboratory LAVIMO measurements like heart rate, heart rate variability, breathing and arterial blood oxygenation are performed parallel to standard polysomnography measurements and subsequently compared to the data of the standard polysomnography. The LAVIMO sensor system consists of the in- ear sensor, the electronics and a PC; the individually formed sensor is embedded into an ear mould for proper fit inside the ear canal. Inside two LEDs emit light into the adjacent skin at 760 and 905 nm wavelengths. The intensity of the backscattered light is detected by a photo detector. In the electronics, the control signals for the LEDs are provided, as well as the photo detector signal is further processed and A-D converted. The electronics also provide a wireless connection to the PC via bluetooth. Data recording, post processing and displaying are tasks of the PC. The feasibility of non- intrusive 24 hours and non-invasive measurements like heart rate, heart rate variability, breathing and oxygen saturation is proved via this minimized sensor and electronics placed at a suitable place at the body guaranteeing high wearing comfort. This includes a wireless data communication for unrestricted mobility. Subsequently the data are compared to the standard polysomnography data to extract vital signs or for example to recognize possible phases of sleep apnoea. The goal in future refering to preventive medical monitoring will be early detection of risk factors for patient's health and improvement of living conditions.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Basic Science
Masking
None

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • patients > 18 years who routinely have to undergo a polysomnography night
  • sleep apnoea patient
  • able to give informed consent

Exclusion Criteria

  • cochlea implant
  • severe lung diseases
  • allergy against material of the sensor
  • inflammation of the middle ear
  • inflammation of auditory canal
  • occlusion because of cerumen
  • electric implants

Outcomes

Primary Outcomes

Extraction of vital signs out of measurement data via individually formed in-ear sensor system in comparison to standard polysomnography data in sleep laboratory

Time Frame: one night

during one polysomnographic night in sleep laboratory the patient will receive the LAVIMO in- ear sensor system and vital parameters like heart rate, heart rate variability, breathing and oxygen saturation will be monitored. Subsequently the data will be processed and compared to the standard polysomnographic data

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor Class
Other
Responsible Party
Sponsor

Study Sites (2)

Loading locations...

Similar Trials