MedPath

Low-add Multifocal vs. Monofocal IOLs

Not Applicable
Conditions
Cataract
Interventions
Device: Low-add multifocal IOL
Device: Monofocal IOL
Registration Number
NCT03749161
Lead Sponsor
Prim. Prof. Dr. Oliver Findl, MBA
Brief Summary

Compare low-add multifocal IOLs with monofocal IOLs to evaluate if patients in the low-add multifocal IOL group have better unaided distance visual acuity compared to the monofocal group.

Detailed Description

Spectacle independence is one of the main aims in modern cataract surgery. Although bilateral monofocal IOL implantation, aiming for emmetropia or low myopia, leads to high levels of patient satisfaction in distance vision, spectacle dependence for intermediate vision, reading and other near vision tasks is the usual result.

There are different techniques to reduce spectacle dependence, the most common one is the use of multifocal IOLs. However, a variable number of patients complain of problems, such as glare or haloes (positive dysphotopsia symptoms). Dysphotopsia symptoms may vary significantly from patient to patient. The real incidence of dysphotopsia like symptoms after cataract surgery and multifocal IOL is unknown and the implantation of multifocal IOLs is a commonly accepted contraindication in patients who are night drivers. Another characteristic of many multifocal IOLs is that it can provide patients with excellent near and distance vision but lack in the intermediate range.

One option to enhance intermediate vision and to leave patients with good contrast sensitivity is the use of low-add multifocal IOLs. These IOLs are adequate to expectations a lot of patients have, who were used to have a good distance vision and who were wearing spectacles when performing near vision tasks before surgery. Many of these patients would prefer to keep their reading spectacles after surgery and ideally would like to function well at distance and intermediate (60 to 80 cm - computer distance, household work...) range without glasses.

One example of these low-add multifocal IOLs is the LENTIS Comfort MF15 with a near add of 1.50D (on IOL plane). Its single, blended transition zone works to deliver patients the same kind of distance vision as a monofocal IOL with the addition of enhanced intermediate vision. In particular, this design provides improved vision at a distance of 60 cm and more. Additional key features of the Comfort IOL include good contrast sensitivity for twilight vision, optimized depth of focus, and natural imaging quality and color sensitivity. Especially this type of IOL may lead to more tolerance of postoperative refractive errors due to biometry and IOL power calculation imprecision. This should result in better unaided distance vision and therefore higher patient satisfaction after cataract surgery.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
50
Inclusion Criteria
  • Age-related cataract in both eyes
  • Scheduled for bilateral cataract surgery
  • Motivated to be less spectacle dependant in the distance to intermediate vision range
  • Patients with an expected BCDVA of 0.8 snellen score or better after surgery
  • Patients with the need of an IOL Power in the range of 10 to 30D (biometry performed with the IOL master 700)
  • Age 21 and older
  • Written informed consent prior to recruitment
Exclusion Criteria
  • Pregnancy (pregnancy test will be taken pre-operatively in women of reproductive age)
  • Retinopathia pigmentosa
  • Chronic uveitis
  • Amblyopia
  • Pupil decentration > 1mm center shift
  • preceded retinal surgery
  • preceded Laser-in-situ-Keratomileusis (LASIK)
  • Any ophthalmic abnormality that could compromise visual function or the measurements

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Lentis comfortLow-add multifocal IOLPatient will receive the low-add multifocal IOL during cataract surgery
Lentis L-313Monofocal IOLPatient will receive the monofocal IOL Lentis L-313 during cataract surgery
Primary Outcome Measures
NameTimeMethod
Spectacle independence questionnaire12 months

Spectacle independence will be assessed using a questionnaire. In this questionnaire the patient will be asked about usage of spectacles for far, near and intermediate distance. Best result will be if the patient is independent from any spectacles in the different distances.

Secondary Outcome Measures
NameTimeMethod
Best Corrected Distance Visual Acuity and Uncorrected Intermediate Visual Acuity12 months

Best corrected distance and uncorrected intermediate visual acuity will be assessed using the ETDRS charts

Titmus Fly Stereo test12 months

Stereo Vision assessment will be done using the Titmus Fly Stereo test. The patients will be asked to detect stereoscopic objects of different difficulty levels. The result will be better, the more correct stereoscopic objects the patient will detect.

Trial Locations

Locations (1)

Vienna Institute for Research in Ocular Surgery (VIROS)

🇦🇹

Vienna, Austria